Dacor ER30DSRCNGH Benutzung Und Pflege

Seite von 36
30
Before You Call for Service
Problem Solution Guide - Cooktop
Problem
May Be Caused By
What to Do
Igniters do not spark.
Power not supplied to unit.
Have electrician connect range to properly 
wired electrical connection.
Power to range is off.
Turn power on at junction box. Check for 
tripped circuit breaker or blown fuse.
Wet or dirty igniter.
Clean according to Care and Cleaning sec-
tion.
Power outage.
Contact power company.
No flame.
Igniter not working (no clicking 
sound).
Clean according to Care and Cleaning sec-
tion.
Wet or dirty igniter.
Clean and dry according to Care and Clean-
ing section.
Gas is turned off.
Make sure the gas supply valve is in the on 
position.
Gas supply interrupted.
Contact gas company.
Flame is distorted, yellow or 
very large. 
Burner ring or burner cap is dirty 
or clogged.
Clean and dry according to Care and Clean-
ing section.
Burner ring or burner cap not prop-
erly positioned.
Make sure burner is assembled according to 
the Setting Up Your Range section.
Range set up to use a different 
type of gas (Natural or LP) or set 
up for different altitude.
Have qualified service technician check to 
make sure that the range is set up for the 
type of gas and the correct altitude.
Gas regulator is not installed or 
faulty.
Have qualified service technician check the 
gas regulator.
Igniter continues to spark 
(click) after flame ignites.
Burner is cold.
Burners may continue to spark for up to 60 
seconds when cold and set to low. See Oper-
ating the Cooktop section for more informa-
tion on how to minimize.
Flame distorted by air draft.
Minimize any air drafts around the range. 
Close nearby windows.
Wet or dirty igniter.
Clean and dry according to Care and Clean-
ing section.
Burner ring or burner cap is dirty.
Clean and dry according to Care and Clean-
ing section.
Burner ring or burner cap not prop-
erly positioned.
Make sure burner is assembled according to 
the Setting Up Your Range section.
Flame goes out at low setting.
Air intake holes obstructed.
Check to make sure air holes above knobs are 
not blocked.
Low gas pressure.
Contact gas company.