Dacor ER36DCNGH Designanleitung

Seite von 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.15
Epicure
®
 Ranges
ER36D, ER48D
1/2
GAS - ELECTRICAL ACCESS DIMENSIONS
Model
A
B
C
D
E*
ER36D
5 5/8” 
(142.9mm)
18 3/8” 
(466.7mm)
10 3/4” 
(273.0mm)
13 11/16” 
(347.7mm)
7/8” 
(22.2mm)
ER48D
3 13/16” 
(96.8mm)
18 11/16” 
(474.7mm)
9 3/8” 
(238.1mm)
13 3/4” 
(349.3mm)
1 1/8” 
(28.6mm)
* The diameter on models equipped for use in Canada is ¼” 
(6.4mm) larger than those stated. Canadian units come from 
the factory pre-wired with an appliance cord. When installing an 
appliance cord on models that are not pre-wired, the hole size must 
be increased to 1 1/8” (1 3/8” for model ER48D) by removing the 
conduit bracket inside the range electrical access box.
48” (1219mm)
**
**
**
** Optional
1 1/16” (27mm) to cooking
surface (top of grates) from
top of trim
Finished Side
Panel
Width:  ER36D - 35 7/8” (911mm)
 
ER48D - 47 7/8” (1216mm)
 NOTES: 
1.   When installing a backguard, always install it 
before sliding the range into place.
B
A
C
D
Gas Regulator Access, 
Cover Removed
Range Electrical Access, 
Cover Removed
E  Electrical Connection 
    Hole in Bottom
Inlet
Back of Range
Revised
03/10/09
All tolerances: +/- 1/16” (+/- 1.6mm) unless otherwise stated
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas 
Supply Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure 1/2 p.s.i. for all models
 WARNING
Observe all governing codes and ordinances during 
planning and installation.  Contact your local building 
department for further information.
This appliance must be installed in accordance with the 
accompanying installation instructions.
ELECTRIC CIRCUIT REQUIREMENTS
Range Model
Circuit Required
Total Connected Load
ER36D
240 Vac, 4-wire* 60 Hz, 
30 Amp. (Min.) 40 Amp. 
(Recommended)
6.5 kW (28 Amp.)
ER48D
240 Vac, 4-wire* 60 Hz, 
50 Amp.
10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground