Dacor ER48DSCHNG Designanleitung

Seite von 2
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
ER36D, ER48D
Renaissance 36” and 48” Wide 
Dual Fuel Ranges
Document # PG05-004
Revised 09/08/14   Page 2/2
CUT-OUT DIMENSIONS
Range Model
F
G
H
ER36D
42” (106.7 cm)* 
36” (91.4 cm)**
36 1/16”  
(91.6 cm)**
33 1/2” 
(84.8 cm)
ER48D
54” (137.2 cm)* 
48” (121.9 cm)**
48 1/16”  
(122.1 cm)**
43 1/2” 
(110.2 cm)
* Recommended 
**Minimum
Gas and Electrical Service
 
For replacement purposes, the location of the existing utilities may 
be utilized provided they do not interfere with the sides or rear of the 
range. Check local building codes for permissible locations.
 
An external manual shut-off valve must be installed between the gas 
inlet and the range, for the purpose of turning on or shutting off gas to 
the appliance. 
The installation must allow for the following:
 
Access to the gas shut-off valve when the unit is installed. 
 
Access to the remote circuit breaker panel/fuse box, when the range 
is in place.  
 
The gas supply piping and shut-off valve, and the electrical junction 
box/receptacle must be located so they do not interfere with the range 
when it is installed.
 
The junction box and gas shut off valve must be located so that 
the range can be pulled out for service while the appliance remains 
connected. 
Note 2
F
G
2
 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
3
 Vertical distance from range top panel level.
1
 Vertical to combustible surface from range grate level; if 
installing an overhead vent hood, also check the hood 
specifications for minimum required clearances. 
Non-combustible 
surface along 
back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2  cm)
min.
1
36 1/2” 
(92.7 cm)
max.
13” (33.0 cm)
max.
4
18” (45.7 cm)
min.
3, 4
Suggested 
location of 
utilities
 
3
4
 This specification does not apply for cabinets more 
than a horizontal distance of 10” (25.4 cm) from the 
edge of the range.
G
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum  Countertop Height:
30 1/4” (76.8 cm) 
Maximum  Countertop Height:
36 1/2” (92.7 cm)
rear wall recommended
Backsplash
3/8" (1.0 cm)
Min. flat countertop
overhang
H
2 13/16"
(7.1 cm)
Note 2
CUTOUT WITH OPTIONAL ERV DOWNDRAFT VENT 
(TOP VIEW)
APPROVED DOWNDRAFT VENT MODELS
Downdraft Vent Model
For Use With 
Range Model
ERV36-ER
ER36D
ERV48-ER
ER48D
Stiffener
Cabinet face**
Countertop*
IMPORTANT: See “CUTOUT WITH OPTIONAL ERV DOWNDRAFT VENT” 
for countertop cutout dimensions.
*** Includes 3/16” (5 mm) space between downdraft vent and range.
** 
IMPORTANT: Cabinet face must not stick out further than
back of control panel.
Back of
control
panel
ERV36-ER or
ERV48-ER
downdraft vent
ER36D or ER48D Range
3/8” Min. (1.0 cm)
space behind
doendraft vent 
chassis to clear
stiffener
3/8” Min. (1.0 cm)
flat countertop
overhang required
behind cutout
31 1/2” min. (80.0 cm)***
Countertop height:
30 1/4" (76.8 cm) min.
36 1/2” (92.7 cm) max.
DOWNDRAFT VENT INSTALLATION SIDE VIEW
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated