Dacor RNR30NI Designanleitung

Seite von 5
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS
Renaissance
 
30” Wide  
Electric Induction Range
Document # PG05-011
Revised 01/28/15   Page 3/5
Note 2
B
A
Non-combustible 
surface along 
back wall
recommended
Top of
finished
counter
Grate 
level
13” (33.0 cm)
max.
4
18” (45.7 cm)
min.
4
C
Suggested 
location of 
utilities
3
Note 5
Note 1
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
A*
B
C
30 1/16” min.
(76.4 cm)
36” (91.4 cm) recommended
30” (76.2 cm) min.
35” (88.9 cm) min. 
37” (94.0 cm) max.
FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - RNR30NS, RNR30NFS, RNR30NIS AND RNR30NIFS
* See the cutout dimensions on following page for self-rimming installations.
 
Failure to meet or exceed the maximum and 
minimum dimensions/clearances stated may result 
in a fire hazard.
 
The shaded area shown denotes the location of 
the electrical junction box/receptacle. This is the 
suggested location. For replacement purposes, the 
location of the existing electrical supply may be 
utilized provided that it does not interfere with the 
sides or rear of the range.
 
Access to the remote circuit breaker panel/fuse box, 
with the range in place and operating, must also be 
allowed for in the installation.
 
The electrical junction box/receptacle must be 
located so that it does not interfere with the range 
when it is installed and under operation. In addition, 
the junction box/receptacle must be located so 
the range can be removed for service and remain 
connected to power.
 
To eliminate the risk of burns or fire by reaching 
over heated surface units, cabinet storage space 
located above surface units should be avoided. If 
cabinet storage space is to be provided directly 
above the range, the risk of personal injury may be 
reduced by installing a range hood.
 
In all instances, installation of a range hood is highly 
recommended. The hood should project horizontally 
a minimum of five (5) inches beyond the face of 
the cabinets. See the range hood specifications for 
minimum clearances.
 
The range may be installed flush to the rear wall. 
See diagram and notes for rear wall surface 
requirements. It is not necessary to install non-
combustible materials behind the range below the 
countertop height.
 
Any openings in the wall behind the appliance or in 
the floor underneath it must be sealed.
1
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood 
or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 
cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. If installing range hood, check the hood specifications for minimum required 
clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See 
Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 1” (2.6 cm) min from edge of range.
5
1” (2.6 cm) min. to combustible side walls above range (both sides).