Viking VRCO5240DLSS Benutzung Und Pflege

Seite von 16
12
Problem
Solution
The refrigeration system runs for
long periods of time
• Check to ensure the condenser area is clean and free of obstructions.
• Check to ensure the door has not beenopen for a long time or more
frequent door openings aren’t occurring.
• Check to ensure warm product hasn’t just been placed in the cabinet.
• On hot days and in warm room temperatures the system will run long.
Condensation forms inside the
refrigerated compartments
• This is normal during high humidity and frequent door openings.
• Check to ensure door is closed and sealing properly.
Condensation forms on the
outside of the unit
• During periods of high humidity some condensation might appear on
outside surfaces. The condensation will disappear when the humidity
drops. Meanwhile, be sure doors are closing and sealing properly.  If
condensation persists, contact your  local authorized servicer.
When pressing the UP button, the
display shows a “Hi” message
followed by a temperature that
does not match the set point.
• If the UP button is pressed without pressing the SET button, the MAX
stored temperature will be displayed. Press the UP button again or wait
5 seconds for the normal temperature to be displayed. To reset the
MAX temperature, press and hold the SET button until the message
“rSt” starts blinking. Release the SET button and the new stored value
will be the current temperature. Frequent and/or extended door
openingsmay cause a higher than expected MAX temperature.
When pressing the DOWN button,
the display shows a “Lo” message
followed by a temperature that
does not match the set point.
• If the DOWN button is pressed without pressing the SET button, the
MIN stored temperature will be displayed. Press the DOWN button
again or wait 5 seconds for the normal temperature to be displayed. To
reset the MIN temperature, press and hold the SET button until the
message “rSt” starts blinking. Release the SET button and the new
stored value will be the current temperature.
Troubleshooting