Dacor ER48DSCHNGH Designanleitung

Seite von 2
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
ER36D, ER48D
Renaissance
®
 36” and 48” Wide 
Dual Fuel Ranges
Document # PG05-004
Revised 09/08/14   Page 1/2
GAS - ELECTRICAL ACCESS DIMENSIONS
Model
A
B
C
D
E*
ER36D
5 5/8” 
(14.3 cm)
18 3/8” 
(46.7 cm)
10 3/4” 
(27.3 cm)
5 5/8” 
(14.2 cm)
7/8” 
(2.2 cm)
ER48D
3 13/16” 
(9.7 cm)
18 11/16” 
(47.5 cm)
9 3/8” 
(23.8 cm)
5 3/4” 
(14.6 cm)
1 1/8” 
(2.9 cm)
* The diameter on models equipped for use in Canada is ¼” (6.4 mm) larger than 
those stated. Canadian units come from the factory pre-wired with an appliance 
cord. When installing an appliance cord on models that are not pre-wired, the hole 
size must be increased to 1 1/8” (1 3/8” for model ER48D) by removing the conduit 
bracket inside the range electrical access box.
48” (121.9 cm)
Front of open door
Front of handle
Front edge of bull nose
Front panel
Rear of front panel/oven door
30 3/4” (78.1 cm)
(48.3 cm)
(90.8 cm)
(94.0 cm)
(7.6 cm)
24” (61.0 cm)
(5.1 cm)
(38.7 cm)
(4.0 cm)
(22.9 cm)
(22.9 cm)
29 3/8” (74.6 cm)
28 1/4” (71.8 cm)
26 1/8” (66.4 cm)
**
**
**
** Optional
1 1/16” (2.7 cm) to cooking
surface (top of grates) from
top of trim
Finished side
panel
Width: 
ER36D - 35 7/8” (91.1 cm)
 
ER48D - 47 7/8” (121.6 cm)
B
A
C
D
Gas regulator access, 
cover removed
Range electrical access, 
cover removed
E  Electrical connection 
    hole in bottom
Inlet
Back of range
Product tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply 
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure 1/2 p.s.i. for all models
 WARNING
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information.
•  This appliance must be installed in accordance with the 
accompanying installation instructions.
ELECTRIC CIRCUIT REQUIREMENTS
Range Model
Circuit Required
Total Connected Load
ER36D
240 Vac, 4-wire* 60 Hz, 30 
Amp. (Min.) 40 Amp.  
(Recommended)
6.5 kW (28 Amp.)
ER48D
240 Vac, 4-wire* 60 Hz, 50 
Amp.
10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground