Dacor ER36DCNG Designanleitung

Seite von 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
8.2
36”, 48” Wide,
Downdraft Raised Vent
Revised
02/03/09
ERV36-ER, ERV48-ER
1/2
Model Number
A
B
ERV36-ER
36” (914 mm)
33 3/8” (848 mm)
ERV48-ER
48” (1219 mm)
43 3/8” (1102 mm)
30 ¼"
(768 mm)
to
37 ¼"
(946 mm)
10"
(254 mm)
30"
(762 mm)
18 5/8”
(473 mm)
5/16” (8 mm)
thick stiffener
across back
3 3/4"
(95 mm)
7/8"
(22 mm)
28" 3 prong 
grounded
power cord
Vent shown
in raised
position
Product 
data label 
Motor
Cover
6"
(152 mm)
2 9/16"
(65 mm)
2 1/2"
(64 mm)
1 15/16"
(49 mm)
 B
 A
Adjustable
Anchor Legs
2 13/16"
(71 mm)
1/4"
(6 mm)
Top cap with
vent down
ERVXX-ER OVERALL 
DImENsIONs
sIDE VIEW
ERVXX-ER OVERALL 
DImENsIONs
FRONt VIEW
 WARNING
1.  
Observe all governing codes and ordinances during planning 
and installation.  Contact your local building department for 
further information.
2.
 
This appliance must be installed in accordance with the 
accompanying installation instructions.
CAbINEt CUtOUt
tOP VIEW
Vertical
non-combustible
surface rear wall
Backsplash
Notch
Countertop
Overhang
See the range planning guide 
for exact countertop dimensions
Countertop Height:
Min: 30 ¼” (768 mm)
Max: 37 ¼” (946 mm)
All tolerances: +/- 1/16” (+/- 1.6mm) unless otherwise stated
NOTE:
1.  Install and use this raised vent only with approved 
Dacor appliances. See the planning guide for 
the particular appliance model for the proper 
applications and cutout specifications.