Dacor DYRTP366SNG Installationsanweisungen

Seite von 20
7
Installation Requirements
NOTE: Gas and electrical connections may only be routed through 
the bottom of the rangetop when installed with a downdraft vent.
Non combustible rear 
wall recommended
10” (2.5 cm) min. to 
combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
3/8” (1.0 cm) min. 
countertop overhang
2 5/8”
(6.7 cm)
Hole 1/2” dia. (1.3 cm), 
2 places, through platform
for hold down bolts 
1/2” (1.3 cm) 
countertop 
overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for raised 
vent, gas and electrical connections
Countertop
Countertop
1/2” (1.3 cm) 
countertop 
overhang
2” (5.1 cm)
11 7/16” 
(29.1 cm)
CL
D
D
E
B
CL
CL
CL
26 5/8”
(67.6 cm)
min. 
cabinet 
depth
Counterop 
overhang
1” (2.5 cm) 
typical
1 3/8”
(3.5 cm) 
max.
15”
(38.1 cm)
Stiffener
Cabinet face
Control panel
overhang
1 3/8” (3.5 cm)
Countertop
Dacor approved
downdraft vent
IMPORTANT: See downdraft
installation instructions for 
duct system layout/planning 
DYRTP366 or 
DYRTP486 rangetop
3/8” min. (1.0 cm)
space behind
downdraft vent 
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Minimum
countertop 
height: 
30 1/4"
(76.8 cm)
Cabinet/Countertop Cutout Dimensions with Downdraft vent - Top View
Cabinet/Countertop with Downdraft vent - Side View