Amana AGR5330B Installationsanweisungen

Seite von 16
15
To Convert Gas Pressure Regulator
1. Open broiler door and remove broiler rack. The gas pressure 
regulator is located in the back right hand corner of the broiler 
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
2. Remove the cap from the gas pressure regulator using a 
flat-blade screwdriver.
NOTE: Make sure sealing washer remains in the same 
position.
3. To convert to Natural gas, unscrew the plastic adjustment 
screw by hand, turn it over, and screw it in again.
4. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners. 
2. Locate Natural gas orifice spuds for top burners in the bag 
containing literature included with the range. Three Natural 
gas spuds are stamped “149” and one is stamped “165.”
3. Remove the LP gas orifice spuds using a 7 mm combination 
wrench. 
4. Install the Natural gas orifice spuds using a 7 mm 
combination wrench. 
A. Gas pressure regulator
A. Cap
Inlet pressure 
to LP gas
Inlet pressure 
to Natural gas
A. Cap
B. Sealing washer
C. Adjustment screw
A
A
C
A
B
180º
A. Burner cap
B. Burner
A. Spud
B. Holder
B
A
A
B