GE GFDN160EJWW Spezifikationenblatt

Seite von 4
Specification Created 3/15
For answers to your Monogram,
® 
GE Profile
 
or GE
®
 appliance questions, visit our website 
at geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
Dryer exhaustinG information – metal Duct only  
For complete information, see installation instructions packed with your dryer.
DuctinG materials: For best performance, this dryer should be vented with 4" 
diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed
flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations,
it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type)
duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where
rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter
can be maintained throughout the entire length of the transition duct. Please see installation 
instruction packed with your dryer for complete instructions when using flexible metal  
(foil type) ducting.
exhaust lenGth calculation:
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the  
  side or bottom of dryer, add one turn.
2.   The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated  
is shown in the table.
  A turn of 45° or less may be ignored. Two 45° turns within the duct length should be  
  treated as a 90° elbow. 
  A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
caution: For personal safety do not terminate exhaust into a chimney, under any  
enclosed house floor (crawl space), or into an attic, since the accumulated lint could  
create a fire hazard or moisture could cause damage. Never terminate the exhaust into  
a common duct or plenum with a kitchen exhaust, since the combination of lint and  
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other 
obstruction with the opening pointed down.
for more information on ventinG kits anD accessories, please call 1-800-Ge-cares.
Listed by 
Underwriters 
Laboratories
Best performance
Domestic  
dryer models
Maximum length of 4"
dia. 
rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4" 
opening
B
2-1/2" 
opening
7.5 cu. ft.
capacity models 
electric dryers
4
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
A
4
B
2-1/2
A
2-1/2
1-3/4
12
3-1/2
Electrical 
Connection
Gas Pipe 
Connection
GfDn160eJ
GE
®
 7.5 cu. ft. capacity frontload electric dryer