Electrolux EW30GC60PS Installationsanleitung

Seite von 5
High standards of quality at Electrolux Home Products, Inc.  
mean we are constantly working to improve our products.  
We reserve the right to change specifications or  
discontinue models without notice.
Electrolux Cooktops /
E30_36DD75ESS Downdraft Vents
Countertop Preparation
2
9
/
16
"
Electrolux Major Appliances, N.A.
USA 
 10200 David Taylor Drive 
 Charlotte, NC 28262   
 1-877-4electrolux (1-877-435-3287) 
 
electroluxappliances.com 
CANADA 
 5855 Terry Fox Way 
 Mississauga, ON L5V 3E4 
 1-800-265-8352 
 
electroluxappliances.ca
DIC_DDV_PREP EL  03/14 
© 2014 Electrolux Home Products, Inc.
Cooktop/Downdraft Vent 
Countertop Preparation Specifications
• 
For detailed Cooktop installation, refer to model-specific product page and 
installation guide on web. Plan installation so that all required minimum 
clearances between cooktop, overhead cabinets and adjacent vertical walls 
are provided.
• 
Position cooktop/vent cutout so all required minimum clearances are met.
• 
Minimum flat countertop area must meet or exceed combined overall width 
and depth as shown. Standard 25" countertop depth may NOT be adequate 
for some cooktop/vent installations, especially with backsplash.
• 
Separate circuits required for cooktop and vent. (Refer to product-specific 
electrical specifications.)
• 
Always consult local and national electric and gas codes. Check local 
building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
• 
For detailed Downdraft Vent installations, refer to model-specific product 
page and installation guide on web.
• 
Voltage Rating –120V/ 60Hz/15 Amps
• 
Connected Load (kW Rating) @120 Volts = 1.0kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded for safe 
operation.)
• 
Amps @120 Volts = 8.0 Amps
• 
Vent unit outside of building only.
• 
Vent must be installed in vertical orientation only.
• 
1,600 CFM remote exhaust blower (PN#5304444802) included with  
vent – shipped in separate box.
• 
Do not use flexible duct. Round duct instead of rectangular duct 
recommended, especially when elbows are required.
• 
When multiple elbows are necessary, ensure a minimum of 24" of straight 
duct between any two elbows.
• 
Thermal breaks such as short section of nonmetallic duct, should be used  
in areas of extreme cold.
• 
For most efficient airflow exhaust, use a straight run or as few elbows as 
possible.
• 
Cold weather installations should have additional backdraft damper 
installed.
• 
Installing a Downdraft Vent in combination with any gas cooking surface  
will affect optimum burner efficiency.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxappliances.com for detailed instructions.
CooktoP/DowNDrAft VENt
CoUNtErtoP PrEPArAtioN