Maytag MDE18MNAYW Installationsanweisungen

Seite von 60
20
2.  Connect neutral wire (white or center wire) (D) of power supply 
cord under center terminal block screw (A). Tighten screw.
3.  Connect remaining wires under outer terminal block screws 
(F). Tighten screws. Finally, reinstall terminal block to dryer rear 
panel. Secure cover with hold-down screw.
Standard Power Cord Connectors
  Flanged Spade Connector 
Ring Connector
Connecting Neutral Wire
1.  Loosen or remove center terminal block screw (A).
IMPORTANT: A 4-wire connection is required for mobile 
homes and where local codes do not permit the use of 3-wire 
connections. 
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer 
can be moved if needed. 
Strip 5" (127 mm) of outer covering from end of cable, leaving bare 
ground wire at 5" (127 mm). Cut 1
1
2
" (38 mm) from 3 remaining 
wires. Strip insulation back 1" (25 mm). Shape ends of wires into  
a hook shape.
Connecting 3-Wire Connection: Power Supply Cord
Connecting 4-Wire Connection: Direct Wire
ELECTRIC DRYER ELECTRICAL CONNECTIONS 
(FOR U.S.A. ONLY)
Connecting Neutral Ground and Neutral Wires
1.  Remove center terminal block screw (A) and the neutral  
ground wire (B) by removing the green external ground 
conductor screw (C).
A
A
D
A
C
B
F
F