LP/Propane Tank Connection
Outdoor side burners orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly
for connection to a standard 20 lb. LP/Propane cylinder e
eq
qu
uiip
pp
pe
ed
d  w
wiitth
h  a
a  T
Tyyp
pe
e  1
1,,  Q
QC
CC
C--1
1  cco
on
nn
ne
ecctto
orr.. (See LP/Propane tank
requirements on page 6). Hose assembly must comply with Elastomeric Composite Hose and Couplings for Conducting
Propane  and  Natural  Gas,  CAN/CGA-8.1  standard  or  the  Thermoplastic  Hose  and  Hose  Couplings  for  Conducting
Propane and Natural Gas CAN1-8.3 standard.  (See LP/Propane tank requirements below).  Each tank is supplied with a
dust cap.  Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of
propane.
Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a distance exceeding
3 feet (0.91 meters) from the fuel supply per ANSI Z21.24.  Also, in a built-in construction where an LP/Propane tank is
going to be used, there MUST be some type of support (braces, cut-out, etc.) to prevent tank from moving within the
installation. The support must also allow the LP/Propane tank to withstand a horizontal tipping force equal to the weight
of the tank without tipping over. The tank can not tip over or deflect more than 1.00 inch when a 38 lb. horizontal force
is applied to a 20 lb. LP/Propane tank.
Connection:  1/2” (1.3 cm) NPT male with a 3/8” (.95) flare adapter
Operating Pressure:  10.0” W.C.P.
To connect to LP/Propane regulator/hose assembly:
You should always turn the LP/Propane tank main valve “OFF” after each use and during transport of the tank or unit.
First connect the regulator assembly to the grill unit.  Connect to the tank valve by screwing the Type 1, QCC-1 connector
to the LP/Propane tank.  Open the tank valve and check the connection between the regulator and the Type 1, QCC-1
fitting for leaks with a soapy water solution.  If bubbles appear, tighten the connection.  Repeat until all leaks have been
stopped.  A
AL
LW
WA
AY
YS
S  C
CH
HE
EC
CK
K  F
FO
OR
R  L
LE
EA
AK
KS
S  A
AF
FT
TE
ER
R  E
EV
VE
ER
RY
Y  L
LP
P//P
PR
RO
OP
PA
AN
NE
E  T
TA
AN
NK
K  C
CH
HA
AN
NG
GE
E..    A
An
nyy  jjo
oiin
ntt  sse
ea
alla
an
ntt  u
usse
ed
d  m
mu
usstt  b
be
e  a
an
n
a
ap
pp
prro
ovve
ed
d  ttyyp
pe
e  a
an
nd
d  b
be
e  rre
essiissttiivve
e  tto
o  tth
he
e  a
accttiio
on
nss  o
off  L
LP
P//P
Prro
op
pa
an
ne
e  g
ga
ass..
LP/Propane Tank
Requirements
A dented or rusty LP/Propane tank may be hazardous
and  should  be  checked  by  your  tank  supplier.  Never
use a cylinder with a damaged valve. All tanks should
be  equipped  with  an  OPD  (overfilling  protection
device).    This  is  a  DOT  requirement  for  all  tanks
purchased after October 1, 1998 and will ensure that
the tank is not overfilled. The  LP/Propane tank should
be  a  standard  5-gal,  20  lb.  gas  cylinder  tank
approximately  12”  in  diameter  and  18”  high  which
must  be  constructed  and  marked  in  accordance  with
the Specifications for LP/Propane Gas Cylinders of the
U.S.  Department  of  Transportation  (D.O.T.)  or  the
National  Standard  of  Canada,  CAN/CSA-B339,
Cylinders,  Spheres  and  Tubes  for  Transportation  of
Dangerous  Goods;  and  Commission.  The  cylinder
connection device must be compatible with the Type 1,
QCC-1  connector  on  the  outdoor  cooking  appliance.
All  LP/Propane  tanks  must  be  mounted  in  a  vertical
position  for  proper  ventilation.  The  cylinder  must  be
provided  with  a  shut-off  valve  terminating  in  an
LP/Propane gas supply cylinder valve outlet specified.
The cylinder supply system must be arranged for vapor
withdrawal  and  provided  with  a  listed  overfilling
prevention device. If the appliance is stored indoors the cylinder must be disconnected and removed from the appliance. Each
tank is supplied with a dust cap.  Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in
leakage of propane. Cylinders must be stored outdoors in a well-vented area out of the reach of children.
3/8” 
3/8” 
male 
male 
flare 
flare 
adapter
adapter
1/2” 
NPT
from
Manifold
Type 1, 
QCC-1
connector
3/8” male 
flare adapter
Regulator 
Assembly
NOTE: Tank must be 
mounted in vertical position
for proper Ventilation
Leak Testing
Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be
performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks, or immediately check if the smell of gas is detected. 
• Do not smoke while leak testing.  
•  Extinguish all flames.
•  Never leak test with an open flame 
WARNING
DANGER
CAUTION
FOR YOUR SAFETY
Before placing into operation, always check for
gas leaks with a soapy water solution. DO NOT 
USE AN OPEN FLAME TO CHECK FOR LEAKS.
1
OFF
2
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush or
towel to apply the solution to the fittings.
Note: For LP/Propane units, check with a full cylinder.
Check that all control knobs are in the “OFF” position.
4
Apply the soap solution to fittings.
Turn cylinder valve knob counter clockwise one
turn to open.
3