A qualified electrician must perform a ground continuity 
check on the wall receptacle before beginning the  
installation to ensure that the outlet box is properly 
grounded. If not properly grounded, or if the wall  
receptacle does not meet electrical requirements noted 
(under ELECTRICAL REQUIREMENTS), a qualified electrician  
should be employed to correct any deficiencies.
WARNING:
  
5LVNRI(OHFWULF6KRFN 
Can cause injury or death: 
5HPRYHKRXVHIXVHRU 
RSHQFLUFXLWEUHDNHUEHIRUH
EHJLQQLQJLQVWDOODWLRQWRDYRLG
VHYHUHRUIDWDOVKRFNLQMXU\
WARNING:
5LVNRI(OHFWULF6KRFN 
Can cause injury or death: THIS APPLIANCE MUST BE 
PROPERLY GROUNDED WRDYRLGVHYHUHRUIDWDOVKRFN
120 V Models
The power cord of this 
appliance is equipped with  
a three-prong (grounding)  
plug which mates with  
a standard three-prong  
(grounding) wall receptacle  
to minimize the possibility  
RIHOHFWULFVKRFNKD]DUG 
from this appliance.
240 V Models
IMPORTANT SAFETY INSTRUCTIONS
3
ELECTRICAL REQUIREMENTS
Installation Instructions
Ensure proper 
ground exists 
before use.
NEMA 14–30R  
Wall Receptacle
Ensure proper 
ground exists 
before use
CAUTION:
 For personal safety, the 
mounting surface must be capable of supporting the 
cabinet load, in addition to the added weight of this 
²SRXQGSURGXFWSOXVDGGLWLRQDORYHQORDGVRIXS
to 50 pounds or a total weight of 113–135 pounds.
CAUTION:
 For personal safety, this product 
cannot be installed in cabinet arrangements such as an 
island or a peninsula. It must be mounted to BOTH a top 
cabinet AND a wall.
CAUTION:
7RDYRLGWKHULVNRISHUVRQDO
LQMXU\ EDFNLQMXU\RURWKHULQMXULHVGXHWRH[FHVVLYH
ZHLJKWRIWKHPLFURZDYHRYHQ RUSURSHUW\GDPDJH\RX
ZLOOQHHGWZRSHRSOHWRLQVWDOOWKLVPLFURZDYHRYHQ
Where a standard two-prong wall receptacle is 
encountered, it must be replaced with a properly 
grounded three-prong wall receptacle, installed by a 
qualified electrician.
WARNING:
5LVNRI(OHFWULF6KRFN 
Can cause injury or death: DO NOT, under any 
FLUFXPVWDQFHVFXWGHIRUPRUUHPRYHDQ\RIWKHSURQJV
from the power cord. Do not use with an extension cord. 
Failure to comply may cause fire.
The wall outlet receptacle 
recommended for this 
application is NEMA #14-
30R and accepts the four-
prong grounded plug of 
this appliance.
120 V Models
This product requires a three-prong grounded outlet. 
Product rating is 120 volts AC, 60 Hertz, 15 amps,  
and 1.70 kilowatts. This product must be connected  
to a supply circuit of the proper voltage and frequency. 
Wire size must conform to the requirements of the 
National Electrical Code or the prevailing local code  
for this kilowatt rating. The power supply cord and  
plug should be brought to a separate 15 to 20 ampere 
branch circuit single grounded outlet. The outlet box 
should be located in the cabinet above the oven and away 
from any potential microwave oven ducting.The outlet 
box and supply circuit should be installed by a qualified 
electrician and conform to the National Electrical Code or 
the prevailing local code.
 240 V Models
This product requires a four-prong grounded outlet. 
Product rating is 120/208 or 120/240 volts, 60 Hertz,  
30 amps and 6.5 kilowatts. This product must be 
connected to an individual properly grounded branch 
circuit, protected by circuit breakers or time-delay fuses. 
Wire size must conform to the requirements of the 
National Electrical Code or the prevailing local code for 
this kilowatt rating. The outlet box should be located in 
the cabinet above the oven and away from any potential 
microwave oven ducting. The outlet box and supply circuit 
should be installed by a qualified electrician and conform 
to the National Electrical Code or the prevailing local code.