TROUBLESHOOTING
First try the solutions suggested here or visit our website at www.maytag.com/product_help –
In Canada www.maytag.ca for assistance and to possibly avoid a service call. 
If you experience
Possible Causes
Solution
Dryer Results (cont.)
Odors
Recent painting, staining, or varnishing  
in the area where your dryer is located.
Ventilate the area. When the odors or fumes are gone from the 
area, rewash and dry the clothing.
Steam models only: For steam cycles, 
the water is not properly connected with 
the dryer.
Make sure water is connected to the dryer. Check that water 
inlet hose is connected to both the faucet and dryer’s water inlet 
valve. Check that the water supply is turned on.
Odors are left in garments after wearing.
Steam models only: To remove odors left in garments after 
wearing, select Refresh. The Refresh cycle is best for reducing 
wrinkles from loads left in the dryer too long.
Load too hot
Load removed before cooldown portion 
of cycle complete.
Allow the dryer to complete the cooldown portion of the cycle 
before removing the load.
Using Timed Dry cycle with a high 
temperature setting.
Select a Sensor Cycle with a lower heat setting to avoid 
overdrying the load.
Dryer Displaying Code Message or Cycle Status Indicator Lights Up
“PF” (power failure)
The drying cycle has been interrupted  
by a power failure.
Touch and hold START/PAUSE to restart the dryer. NOTE: The 
Control Lock function may be enabled when recovering from a 
power failure. To unlock the control, touch and hold CONTROL 
LOCK for at least 3 seconds.
“L” or “L2” Diagnostic Code 
(low or no line voltage 
condition)
There may be a problem with your home 
power supply, keeping the dryer’s heater 
from turning on.
The dryer will continue to run when this diagnostic code is 
present. Touch any setting or option name to clear the code  
from the display and return to the estimated time remaining.
Try the following:
Check to see if a household fuse has blown or circuit breaker 
has tripped. Electric dryers use two household fuses or 
breakers. Replace the fuse or reset the circuit breaker.
Confirm that the power cord is properly installed. Refer to  
the Installation Instructions for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
Check Vent indicator is lit
The lint screen or vent is clogged;  
the vent is crushed or kinked or has  
too many turns.
The dryer will continue to run when this diagnostic code is 
present. Touch any setting or option name to clear the code  
from the display and return to the estimated time remaining.
Try the following:
• Clean lint screen.
•  Check to see if the vent run from the dryer to the wall is  
crushed or kinked.
•  Confirm that the vent run from the dryer to the wall is free  
of lint and debris.
•  Confirm that the exterior vent exhaust hood is free of lint  
and debris.
•  Confirm that your vent system falls within the recommended  
run length and number of elbows for the type of vent you are 
using. Refer to “Plan Vent System” in the Installaton Instructions  
for details.
•  Select a Timed Dry heated cycle, and restart the dryer.
•  If the message persists, have your entire home venting run 
cleaned.
“F# E#” (F1 E1, F3 E1, etc.) 
variable service codes
The dryer is in need of service.
If a code beginning with an “F” appears in the display,  
alternating between F# and E#, the dryer control has  
detected a problem that requires service. Call for service.
“Loc” or “Lc”
The Control Lock is enabled.
Touch and hold CONTROL LOCK for 3 seconds to unlock  
the controls of the dryer. During this time the LED Display  
will count down 3-2-1. When the Control Lock is disabled,  
the LED Display will clear.