Maytag MGD3100DW Datenbogen

Seite von 20
W10607131A
Installation Instructions
for W10606694 L.P. (Propane and Butane)
Gas Conversion Kit
Parts included in Kit:
  1  Instruction Sheet
  1  Blocking Pin
  1  Orifice, Burner-Butane No. .049
  1  Orifice, Burner-Propane No. 55
  1  Label, Rating Plate Conversion (English)
  1  Label, Rating Plate Conversion (French)
  1  Label, Conversion Record (English)
  1  Label, Conversion Record (French)
 
1  Label, Burner Baseplate (English/French)
Converting 20,000 BTU/hr Gas Burners from Natural Gas  
to Liquefied Petroleum (Bottled Gas)
NOTE:  A qualified service technician is any person or 
representative of a company who is experienced or trained 
in servicing gas equipment and is familiar with necessary 
precautions.
IMPORTANT:  The LP Conversion Kit you received is an 
approved kit for converting your gas dryer from natural to LP 
propane or butane gas. The kit no. shown on the Burner Data 
Label located on the Burner Base may not match the kit you 
receive due to kit consolidation.
NOTE:  Read these instructions before proceeding.
Canada Only
THIS CONVERSION KIT SHALL BE CARRIED OUT IN 
ACCORDANCE WITH THE REQUIREMENTS OF THE 
PROVINCIAL AUTHORITIES HAVING JURISDICTION AND 
IN ACCORDANCE WITH THE REQUIREMENTS OF THE 
CAN-B49.1 AND CAN1-B149.2 INSTALLATION CODE.
Warning:  This conversion kit shall be installed by a qualified 
service agency in accordance with the manufacturer’s 
instructions and all applicable codes and requirements of 
the authority having jurisdiction. The information in these 
instructions must be followed to minimize the risk of fire or 
explosion or to prevent property damage, personal injury, 
or death. The qualified service agency is responsible for the 
proper installation of this kit. The installation is not proper 
and complete until the operation of the converted appliance 
is checked as specified in the manufacturer’s instructions 
supplied with this kit.
This dryer has been manufactured for use with Natural Gas. 
Installation of this conversion kit converts the dryer for use with 
L.P. gas with supply pressure between 8" (203 mm) and  
13" (330 mm) water column. If this dryer is converted for use 
with L.P. gas by means of this kit, the input rating will be 20,000 
BTU’s per hour, for altitudes up to 10,000 feet (3,048 m). For 
installations above 2,000 feet (610 m), contact a qualified service 
agency for derating instructions.
READ THOROUGHLY AND FOLLOW STEPS
1.  Unplug dryer or disconnect power.
2.  Turn off gas supply using the shut-off valve that supplies  
the dryer.
3.  Open dryer door and remove lint filter screen (on some 
models).
4.  Fill out information on the appropriate Conversion Record 
Label (English or French) and apply in a conspicuous 
location adjacent to model and serial tag located in the  
door well. Go to section 1, 2, or 3 depending on your model.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Section 1 - Clothes Dryer with A Full-Front Panel & Front Mounted Console .... page 2
Section 2 - Dryers with Toe Panel ........................................................................... page 5
Section 3 - Dryers with A Full-Front Panel & Rear Mounted Console ................. page 5