Maytag MED7100DW Benutzung Und Pflege

Seite von 40
15
First try the solutions suggested here or visit our website at www.maytag.com/product_help –
In Canada www.maytag.ca for assistance and to possibly avoid a service call. 
If you experience
Possible Causes
Solution
Door not closed completely.
Make sure the dryer door is closed completely.
Touch and hold START/PAUSE 2–5 seconds.
Household fuse is blown or circuit 
breaker has tripped.
There may be 2 household fuses or circuit breakers for the dryer. 
Check that both fuses are intact and tight, or that both circuit 
breakers have not tripped. Replace the fuses or reset the circuit 
breaker. If the problem continues, call an electrician.
TROUBLESHOOTING
Dryer will not run
Humming or whining noise 
with Steam cycle selected 
(on some models)
Water pump or water inlet valve 
(depending on model) on dryer  
is running.
Unusual Noise
START/PAUSE not touched firmly or 
held long enough.
Dryer Operation
Incorrect power supply.
Electric dryers require 240-volt power supply. Check with a 
qualified electrician.
Wrong type of fuse.
Use a time-delay fuse.
The water pump or water inlet valve on the dryer is used during the 
Steam function. If the dryer has just been installed or unused for an 
extended period, the pump or valve may be louder and run longer. 
This is normal.
NOTE: The valve may make this noise even with no water line connected.
Thumping noise
Dryer hasn’t been used in a while.
This is due to temporary flat spots on the drum rollers.  
The thumping sound will diminish after a few minutes.
Rattling or vibrating 
noise
A small object caught between the 
edges of dryer drum.
Check the front and rear edges of the drum for small objects. Clean 
out pockets before laundering.
Dryer isn’t properly leveled.
The dryer may vibrate if not properly installed. See the Installation 
Instructions. All four dryer feet should be in firm contact with the 
floor.
Clothing is balled up in dryer.
When balled up, the load will bounce, causing the dryer to vibrate. 
Separate the load items and restart the dryer.
Dryer Results
Dryer will not heat
Household fuse is blown or circuit 
breaker has tripped.
The drum may be turning, but you may not have heat. Electric 
dryers use 2 household fuses or circuit breakers. Replace the  
fuses or reset the circuit breaker. If the problem continues, call  
an electrician.
Clothes are not drying  
satisfactorily or drying 
times are too long
Lint screen is clogged with lint.
Clean lint screen before each load.
Run the dryer for 5–10 minutes. Hold your hand under the 
outside exhaust hood to check air movement. If you do not feel air 
movement or air movement is minimal, clean exhaust system of lint 
or replace exhaust vent with heavy metal or flexible metal vent.  
See the Installation Instructions.
The exhaust vent or outside exhaust 
hood is clogged with lint, restricting 
air movement.
Incorrect power supply.
Electric dryers require 240-volt power supply. Check with a 
qualified electrician.
Supply line valve not open.
For gas dryers, make sure that the valve on the gas supply line  
is open.
Clicking noise
Gas valve operating.
On gas dryers, you may hear the gas valve clicking as it opens and 
closes. This is normal.
Energy Saver option is on.
For optimal drying times, turn off Energy Saver. For optimal energy, 
turn on Energy Saver.
Loud humming or 
increased noise during 
cycle
Load is packed tightly or exhaust vent 
is blocked.
Reduce load size to recommended load size in “Cycle Guide.” 
Run the dryer for 5–10 minutes. Hold your hand under the 
outside exhaust hood to check air movement. If you do not feel air 
movement or air movement is minimal, clean exhaust system of lint 
or replace exhaust vent with heavy metal or flexible metal vent.  
See the Installation Instructions.