Frigidaire FFGS3025PW Spezifikationenblatt

Seite von 7
Specifications  
subject to change.
30" Gas Slide-In Range
Frig Baseline
USA
 • 
10200 David Taylor Drive
 • 
Charlotte, NC 28262
 • 
1-800-FRIGIDAIRE
 • 
frigidaire.com 
CANADA
 • 
5855 Terry Fox Way
 • 
Mississauga, ON L5V 3E4
 • 
1-800-265-8352
 • 
frigidaire.ca
FFGS3025P 10/13 
© 2013 Electrolux Home Products, Inc.
Slide-In Ranges
FFGS3025P S / W / B    
30" Gas
Slide-In Range Specifications
• 
Product Shipping Weight (approx.) – 220 Lbs.
• 
Voltage Rating – 120V / 60 Hz / 15 Amps
• 
Connected Load (kW Rating) @ 120 Volts = 0.7  kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
• 
Amps @ 120V = 15 Amps
• 
Always consult local and national electric and gas codes.
• 
Make sure wall coverings around range can withstand heat generated 
by range.
• 
Linoleum or any other synthetic floor covering located beneath range, 
must be capable of withstanding minimum heat of 90° F above room 
temperature without shrinking, warping or discoloring. Insulating pad 
or 1/4"-thick plywood required between range and a carpeted floor.
• 
Do not obstruct flow of combustion air at oven vent nor around base 
or beneath lower front panel of range. Range requires fresh air for 
proper burner combustion.
• 
Range ships with 3/4" factory regulator. 
• 
LP Gas Conversion Kit supplied.
• 
Gas supply piping can be through back wall or floor. Optimum 
location is between 1" and 8" from floor through back wall within  
3" of center line; can also be through floor against back wall within  
12" of center line. Supply line must be equipped with approved 
manual shutoff valve, accessibly located in same room as range.
• 
Countertop MUST be level in all directions and adjustable range 
height at least 1/16" greater than tallest cabinet height, to ensure 
metal rangetop flange will fit properly on countertop edge.
• 
When installing optional Backguard Kit, cutout depth of 21-3/4" 
minimum / 22-1/8" maximum needs increased to 24".
• 
Overhead cabinetry should not exceed a 13" maximum depth.
• 
Absolute minimum horizontal distance between overhead cabinets 
installed to either side of appliance must be no less than maximum 
width of appliance.
• 
Allow 24" minimum clearance between rangetop and bottom of cabinet 
when bottom of wood or metal cabinet is protected by not less than 1/4" 
flame-retardant millboard covered with not less than No. 28 MSG sheet 
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow 30" 
minimum clearance when cabinet is unprotected.
• 
Allow 5" minimum clearance from edge of rangetop to nearest 
combustible wall on either side of unit.
• 
To reduce risk of fire when using overhead cabinetry, install range  
hood that projects horizontally a recommended minimum of 5" beyond 
bottom of cabinets.
Countertop Preparation 
Rangetop’s side flanges overlap countertop cutout edges – for detailed 
preparation instructions, refer to product installation guide on the web.
• 
Flat Square-Finish Countertops – require no preparation since 
rangetop’s flange lays directly on countertop edge. 
• 
Formed Front-Edged Countertops – require front molded edge to  
be shaved flat 3/4" from each front corner of opening. 
• 
Tile Countertops – may need trim cut back 3/4" from each front corner 
of opening and /or rounded edge flattened. 
• 
For existing cutout width greater than 30-1/16" reduce the 3/4" overlap 
dimension; for cutout width of 29", replace actual side  
trim panels with smaller side trim panels, available with optional  
Side Trim Kit (refer to detailed kit installation instructions).
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• 
Rear Filler Kit: Stainless Steel – (PN # 901193-901S), 
White – (PN # 901193-9011), Black – (PN # 901193-9010).
• 
Side Panel Kit: Stainless Steel – (PN # 903074-901S),  
White – (PN # 903074-9011), Black – (PN # 903074-9010).
• 
Backguard Kit: Stainless Steel – (PN # 903046-901S),  
White – (PN # 903046-9011), Black – (PN # 903046-9010).
• 
Side Trim Kit: Stainless Steel – (PN # 903075-901S),  
White – (PN # 903075-9011), Black – (PN # 903075-9010).