Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that the 
ground path and wire gauge are in accordance with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating plate. 
The model/serial/rating plate is located behind the control 
panel. Refer to the figures in “Product Dimensions” in the 
“Location Requirements” section.
This range is manufactured with the neutral terminal connected 
to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power 
supply cord (pigtail) (see the following Range Rating chart). If 
local codes do not permit ground through the neutral, use a 
4-wire power supply cord rated at 250 volts, 40 or 50 amps and 
investigated for use with ranges.
*The NEC calculated load is less than the total connected load 
listed on the model/serial/rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker box 
(or fused disconnect) through flexible or nonmetallic sheathed, 
copper or aluminum cable. See the “Electrical Connection - 
U.S.A. Only” section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of 
the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the 
range.
The wiring diagram is located on the Tech Sheet.
The Tech Sheet is located on the back of the range inside a 
clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the 
neutral by a link. The ground must be revised so the green ground 
wire of the 4-wire power supply cord is connected to the cabinet. 
See “Electrical Connection - U.S.A. Only” section.
Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50P plug on the 
supply end. 
The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief and 
be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power 
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord contains 
3 copper conductors with ring terminals or open-end spade 
terminals with upturned ends, terminating in a NEMA Type 10-50P 
plug on the supply end. Connectors on the appliance end must be 
provided at the point the power supply cord enters the appliance. 
This uses a 3-wire receptacle of NEMA Type 10-50R.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)