LOCATION REQUIREMENTS
Proper installation is your responsibility. 
You will need: 
n
A water heater set to 120° F (49° C).
n
A grounded electrical outlet located within 6 ft (1.8 m) of 
power  cord on back of washer.
n
Hot and cold water faucets located within 4 ft (1.2 m) of hot  
and cold water fill valves on washer, and water pressure of  
20-100 psi (137.9-689.6 kPa).
n
A level floor with maximum slope of 1" (25 mm) under entire 
washer. Installing on carpet or surfaces with foam backing is  
not recommended.
n
Floor must support washer’s total weight (with water and load)   
of 315 lbs (143 kgs).
IMPORTANT: Do not install, store or operate washer where  
it will be exposed to weather or in temperatures below 32° F  
(0° C). Water remaining in washer after use may cause damage  
in low temperatures. See “Washer Care” in your “Use and Care 
Guide” for winterizing information.
33"
(838 mm)
1
/
2
" - 1"
(13 mm - 25 mm)
27"
(686 mm)
38.5"
(978 mm)
52.6"
(1336 mm)
Alternate Inlet Hoses: 
(may be required for some  
installations, not supplied with washer) 
n
8212656RP  10 ft. (3.0 m) Inlet hose, Black EPDM (2 pack)
n
8212641RP   5 ft. (1.5 m) Inlet hose, Black EPDM (2 pack) 
n
8212546RP   4 ft. (1.2 m) Inlet hose, Black EPDM (2 pack)
n
8212545RP   5 ft. (1.5 m) Inlet hose, Red and Blue EPDM  
 
(2 pack) 
All dimensions show recommended spacing allowed, except for 
closet door ventilation openings which are the minimum required.
For each arrangement, consider allowing more space for ease of 
installation and servicing, and spacing for companion appliances 
and clearances for walls, doors, and floor moldings. 
Space must be large enough to allow door to fully open.  
Add spacing of 1" (25 mm) on all sides of washer to reduce  
noise transfer. If a closet door or louvered door is installed, top 
and bottom air openings in door are required. 
1"
(25 mm)
1"
(25 mm)
39" min.
(990 mm)
Custom under counter installation:
1"
(25 mm)
5"
(127 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
77
1
/
2
"
(1969 mm)
6"
(152 mm)
1"
(25 mm)
Recessed area or closet installation 
(stacked washer and dryer):
n
8212487RP   5 ft. (1.5 m) Nylon braided inlet hose (2 pack)
n
8212638RP   6 ft. (1.8 m) Nylon braided inlet hose, space  
 
saving 90° elbow, hypro-blue steel couplings  
 
(2 pack)
n
8212637RP   6 ft. (1.8 m) Inlet hose, Black EPDM, space  
 
saving 90° elbow, hypro-blue steel couplings 
 
(2 pack)