5.  Slide the end of the appliance cord into the strain relief from 
the bottom of the box. See facing page.
6.  Connect the white (neutral) wire to the neutral terminal in the 
box.
7.  Connect the L1 wire to the L1 power supply terminal in the 
box.
8.  Connect the L2 wire to the L2 power supply terminal in the 
box.
9.  If using a 4-wire connection, connect the ground wire to 
the grounding screw inside the box using a loop or spade 
terminal.
10.  Tighten the strain relief so that the appliance cord is held 
snuggly in place.
11.  Replace the range electrical access cover.
Installation Instructions
Electrical Connection (cont.)
Appliance Cord Connections - where Local 
Code Permits
 
wARNINg
Do not connect the green appliance wire to the neutral (white) 
supply wire unless local building codes permit.
1.  Remove the range electrical access cover from the back of 
the range.
2.  If using a 4-wire connection, loosen the grounding screw and 
remove the neutral to ground jumper link.
3.  Remove the conduit bracket from the bottom of the range 
electrical box.
4.  Disassemble and remove the strain relief from the appliance 
cord (not included). Insert the tabs on the two parts of 
the strain relief into the hole on the bottom of the box and 
reassemble it so that the tabs are below the box and the 
strain relief itself is inside the box.
Bare wire
connections
Loop and
spade terminal
connections
Remove link on
4-wire installations
Remove conduit
bracket before strain
relief installation
Reassemble with tabs
below and clamp above
Bottom of range
electrical box
Strain relief