Installation Specifications
 WARNING
•  Failure to meet or exceed the maximum 
and minimum dimensions/clearances stated 
may result in a fire hazard.
•  To eliminate the risk of burns or fire by 
reaching over heated surface units, cabinet 
storage space located above surface units 
should be avoided.
•  Carefully check the location where the range 
is to be installed. For best performance, the 
range should be placed away from drafts 
that may be caused by doors, windows and 
heating and air conditioning outlets.
•  To reduce the risk of personal injury and 
to reduce accumulated smoke in the room, 
Dacor strongly recommends installing 
a range hood. A range hood should 
project horizontally a minimum of five (5) 
inches beyond the face of the cabinets. If 
installing a range hood, see the range hood 
specifications for minimum clearances.
•  If cabinet storage space is to be provided 
directly above the range, the risk of personal 
injury may be reduced by installing a range 
hood.
•  The range may be installed flush to the rear 
wall. See diagram and notes for rear wall 
surface requirements. It is not necessary to 
install non-combustible materials behind the 
range below the countertop height.
•  Regardless of the type of back wall surface, 
the range must not be installed or operated 
without the backguard in place.
•  Any openings in the wall behind the 
appliance or in the floor underneath it must 
be sealed.
Cabinet Layout
Note 2
B
A
Back wall
immediately
behind range
6
Top of
finished
counter
13” (33.0 cm)
max.
4
14” (35.6 cm) 
min.
4
C
Suggested 
location of 
utilities
3
Note 5
Note 1
A*
B
C
30” 
minimum 
(76.2 cm)
36” (91.4 cm) 
recommended  
30” (76.2 cm) 
minimum
37” 
(94.0 cm) 
maximum
Freestanding Installation Cabinet Cutout Dimensions - Models DR30GS, DR30GFS, DR30GIS and DR30GIFS
*See cutout dimensions on facing page for 
self-rimming installations.
All tolerances: +1/16” (+1.6 mm), -0 
unless otherwise stated
1 30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. 
clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no 
less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30”  
(76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check 
the hood specifications for minimum required clearances.
2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See 
Product Dimensions.
3 Consult local code and page 8 for requirements.
4 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5 10” (25.4 cm) min. to combustible sidewalls above range (both sides).
6 Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, 
whichever is lower. Non-combustible surface recommended, but not required, for models DR30GS and DR30GFS.