Electrical connection
 
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the 
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is 
about 1W for 5 gas burner version or 2W for 6 gas burners version. 
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) 
grounding plug for your protection against shock hazard and should be plugged directly into a 
properly grounded receptable. Do not cut or remove the grounding prong from this plug.   
 
Wiring diagrams
    
 
 
 
Wiring diagram description  
see Fig. 12.  
 
 
 
 
 
1. Cable terminal 
 
 
 
 
 
 
 
2. Ignition switch 
3. Spark generator 
4. Ignition spark 
L. Black 
N. White 
T. Green (earth) 
 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 
Conversion to different types of gas 
Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 
To change the nozzles of the burners  use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 
 
TABLE A: Adapting to different types of gas     
Burner
 
Position 
Inj. size
 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass size 
 
 
1/100mm 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
[1/100mm] 
Auxiliary
 
Front R 
92 
NG 
4” 
3750 
1098 
900 
264 
Regulated 
 
 
56 
LP(Propane) 
11” 
3750 
1098 
900 
264 
29 
Semi-Rapid
 
Rear L 
117 
NG 
4” 
6000 
1759 
1500 
439 
Regulated 
 
 
73 
LP(Propane) 
11” 
6300 
1845 
1500 
439 
36 
Rapid
 
Rear R 
155 
NG 
4” 
10400 
2046 
2500 
732 
Regulated 
 
 
98 
LP(Propane) 
11” 
11400 
3339 
2500 
732 
47 
 
Front L Inner 
80 
NG 
4” 
 
 
900 
264 
Regulated 
Dual 
 
50 
LP(Propane) 
11” 
NG   17000 
4980 
29 
burner 
Front L Outer 
N°2 x 130 
NG 
4” 
LP    18800 
5507 
Regulated 
 
 
N°2 x 83 
LP(Propane) 
11” 
 
 
65 
CAUTION: save the orifices removed from the appliance for future use  
Regulation of burners 
Regulation of the "MINIMUM" on the burners 
To regulate the minimum on the burners carry out the following procedure indicated below: 
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ). 
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of 
the tap itself. 
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower 
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until 
the flame of the burner is regulated in the most suitable way to MINIMUM. 
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the 
MINIMUM position.  
ATTENTION: The regulation described above can be carried out only with burners using natural gas, 
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.