Ventilation Hood Insert
EI36HI55K S
36" Ventilation Hood Insert Specifications
Product Weights: Hood Insert – 28 lbs.; Integrated Blower – 20 lbs.  
(1200 CFM) / 11 lbs. (600 CFM); Remote Blower – 37 lbs. (1200 CFM) / 
29 lbs. (600 CFM)
 
36" Vent Hood Insert requires custom-built enclosure with installation 
of Integrated Blower Motor System (1200 or 600 CFM) into upper hood 
insert’s housing; or optional Remote Blower Motor System (1200 or  
600 CFM) in separate location. (For installation details and specifications, 
refer to Product Installation Guide on web.)
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.81 kW
 
(1200 CFM) /  
0.40 kW
 
(600 CFM). (For use on adequately wired 120V, dedicated circuit 
having 2-wire service with a separate ground wire. Appliance must be 
grounded for safe operation.)
Amps @ 120 Volts = 7.4 Amps (1200 CFM) / 3.7 Amps (600 CFM)
Always consult local and national electric codes. Check local building 
codes for installation requirements, as they may vary per locale. 
Makeup air systems may be required by local building codes when 
using ventilation systems greater than specified CFM of air movement. 
Specified CFM varies per locale.
 Custom-built enclosure required, with hood cabinet having 22" min. hood 
insert depth and 36" width between cabinet opening above cooking 
surface. Structure and support must be capable of supporting 75 lbs.
 Locate hood insert away from strong draft areas.
 Minimum installation height allowed from bottom of hood canopy  
to cooking surface is 24" for electric and 30" for gas. (NOT more than  
36" recommended.)
Vent system MUST terminate outdoors through roof or wall; do NOT 
terminate into attic or other enclosed area.
Exhaust opening has 10" diameter round vent outlet. For installations 
using 600 CFM Blower Motor System, 6" or 8" round vent system 
recommended; for 1200 CFM, 10" round should be used. (If smaller  
round vent system is used, sound level will be louder.)
 
To provide efficient performance, length of vent system and number of  
elbows should be kept to minimum. Flexible vent greatly reduces 
performance and is not recommended.
Use metal vent only – rigid metal vent recommended; plastic or metal foil 
vent not recommended.
For cold weather installation, additional backdraft damper and thermal 
break should be installed. Thermal break will minimize conduction of 
outside temperatures as part of the vent system with damper on cold air 
side of break, as close as possible to where vent system enters heated 
portion of house.
Optional Remote Blower Motor System Specifications
Remote Blower installs separately from insert and MUST mount to secure 
roof, ceiling, wall, floor or new/existing frame construction; spanning studs or 
mounted to plywood between ceiling joists or roof rafters and may require 
additional framing. (For installation details and specifications, refer to Typical 
Venting Installations on this page and Product Installation Guide on web.)
 Structure and support MUST be capable of supporting 50 lb. weight.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxappliances.com for detailed instructions.
Blower Motor System Options
Integrated Blower Motor System Kits:  
1200 CFM – (PN # EI12HIPIKS), 600 CFM – (PN # EI06HIPIKS).
Remote Blower Motor System Kits:  
1200 CFM – (PN # EI12HIPRKS), 600 CFM – (PN # EI06HIPRKS).
36" Ventilation Hood Insert