Thermador PRD304GHU Installationsanweisungen

Seite von 72
English 5
than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick 
stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 
inch (0.5 mm) thick copper. Flame retardant materials bear 
the following mark:
UNDERWRITERS LABORATORIES INC. CLASSIFIED 
MINERAL AND FIBER BOARDS SURFACE BURNING 
CHARACTERISTICS
 
Followed by the flame spread and smoke ratings. These 
designations are shown as “FHC (FIame Spread/Smoke 
Developed).” Materials with “O” flame spread ratings are 
flame retardant. Local codes may allow other flame spread 
ratings.
4. Any openings in the wall behind the range and in the 
floor under the range must be sealed.
5. When there is less than a 12" horizontal clearance 
between combustible material 
 and the back edge of 
the range above the cooking surface, a Thermador 
Low Back or Pot and Pan Shelf must be installed. (See 
Figure 2). When clearance to combustible material 
 
is over 12", a Thermador Flush Island Trim may be 
used. Figure 2 indicates the space required for each 
type of backguard.
6. Always keep appliance area clear and free from 
combustible materials, gasoline and other flammable 
vapors and liquids.
7. Do not obstruct the flow of combustion and ventilation 
air to the unit.
8. A (10) inch minimum clearance is needed when the 
range is installed beside a combustible side wall.
 
A
s defined in the “National Fuel Gas Code” (ANSI 
Z223.1, Current Edition).
Δ
Δ
Δ