www.Dacor.com      Phone: (800) 793-0093  
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
5.15
Distinctive Range
DR30D
Note 2
E
F
2
 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
3
 Consult local code for exact location requirements.
1
 Vertical to combustible surface from range grate level; if 
installing an overhead vent hood, also check the hood 
specifications for minimum required clearances. 
Non-combustible 
surface along 
back wall
recommended
10” (25.4 cm) Min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
Min.
1
37 7/8
(96.2 cm)
Max.
13” (33.0 cm)
Max.
4
18” (45.7 cm)
Min.
1, 4
Suggested 
location of 
utilities
 
3
4
 Not applicable for cabinets more than a horizontal 
distance of 10” (25.4 cm) from the edge of the range.
Cutout Dimensions
E
F
36” (91.4 cm)*
30” (76.2 cm)**
30 
1
/
16
” (916mm)
* Recommended 
** Minimum
gas and Electrical Service
The shaded area shown below denotes the location of the gas inlet 
 
and the electrical junction box/receptacle. This is the recommended 
location. For replacement purposes, the location of the existing 
utilities may be utilized provided they do not interfere with the sides 
or rear of the range. Check local building codes for permissible gas 
valve locations.
An external manual shut-off valve must be installed between the gas 
 
inlet and the range for the purpose of turning on or shutting off gas to 
the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. 
 
Access to the remote circuit breaker panel/fuse box when the range 
 
is in place.  
The gas supply piping, gas shut-off valve and the electrical junction 
 
box or receptacle must be located so they do not interfere with the 
range when it is installed.
The junction box and gas shut off valve must be located so that 
 
the range can be pulled out for service while the appliance remains 
connected. 
Cabinet Layout
Carefully check the location where the range is to be installed. For 
 
best performance, the range should be placed away from drafts that 
may be caused by doors, windows and heating and air conditioning 
outlets.
To reduce the risk of personal injury and to reduce accumulated 
 
smoke in the room, Dacor strongly recommends installing a range 
hood. A range hood should project horizontally a minimum of five (5) 
inches beyond the face of the cabinets.
All maximum and minimum dimensions and clearances shown in the 
 
diagram below must be maintained for safe operation.
The range may be installed flush to the rear wall. A non-combustible 
 
rear wall is not mandatory, but Dacor highly recommends installing 
a non-combustible material from the countertop level up to the vent 
hood or installation of a backguard.
Any openings in the wall behind the appliance or in the floor 
 
underneath it must be sealed. 
REqUIRED cAbINEt DImENsIoNs
Cabinet tolerances: -1/16”, (+1.6mm) -0
Document # PG05 - 006
Revised 1/26/10    Page 2/2