Dacor ER30GSCHLPH Designanleitung

Seite von 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.6
30” Wide, Epicure™
All Gas Range
ER30G
2/2
Revised
10/08/08
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
nOTES:
1.   Utilities may be located in the lower left 
corner of the adjacent right cabinet. 
(recommended)
2.  Contact your local building department 
to verify compliance with local code 
interpretation.
Model number
“a”
“B”
ER30G
30 1/16” (764mm)
30” (762mm) Minimum
36” (914mm) Recommended
**
** Cabinet depth is at discretion of customer 
but cabinet face MUST NOT protrude further 
than rear of front panel, see product dimesions
*** Consult local code for exact location 
requirements.
* Vertical to combustible surface
B
A
Non-Combustible 
surface along 
back wall
recommended
Suggested 
location of 
utilities***
30” (762mm)
min.*
cUtOUt DImENsIONs
12 1/2”
(31.8 cm)
to
14 5/8”
(37.1 cm)
2 5/8”
(66.7 cm)
bAck Of RANGE
gaS SUPPLY PrESSUrE rEQUirEMEnTS
gas 
Type
Manifold 
Pressure* (wC)
Min. gas Supply 
Pressure (wC)
Max. input 
Pressure
Natural
5”
6”
1/2 p.s.i.
LP
10”
11”
1/2 p.s.i.
iMPOrTanT: The information above is for reference only. If the 
above data does not agree with the product data label, use the 
data on the product data label on top of the kick plate below the 
door (remove the door according to the installation instructions to 
view it).
The gas connection is located on the back of the unit as shown.