Electrical: To properly install your range, you must determine the type 
of electrical connection you will be using and follow the instructions 
provided for it here.
•  Range must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating plate. The 
model/serial number rating plate is located on the left side frame 
behind the storage drawer panel or behind the top right side of the 
oven door. Refer to the figures in the “Product Dimensions” section  
of the “Location Requirements” section.
•  This range is manufactured with the neutral terminal connected to 
the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply 
cord (pigtail) (see following Range Rating chart). If local codes do 
not permit ground through the neutral, use a 4-wire power supply 
cord rated at 250 volts, 40 or 50 amps and investigated for use 
with ranges.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 – 16.5 KW
7.8 – 12.5 KW
40 or 50 **
16.6 – 22.5 KW
12.6 – 18.5 KW
50
 *  The NEC calculated load is less than the total connected load listed 
on the model/serial rating plate.
**  If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. 
For 50-amp rated cord kits, use kits that specify use with a nominal
 
1
3
/
8
" (34.9 mm) diameter connection opening.
• A circuit breaker is recommended.
A
B
C
D
E
F
A. 27
3
/
4
" (70.5 cm) max. depth with handle
B.  46
7
/
8
" (119.1 cm) overall height (max.) with leveling legs 
screwed all the way in*
C.  36" (91.4 cm) cooktop height (max.) with leveling legs 
screwed all the way in*
D.  29
7
/
8
" (75.9 cm) width
E.  25
5
/
16
" (64.3 cm) depth – back of range to front of cooktop**
F.  Model/serial rating plate (located on the left side frame behind 
storage drawer or right side of frame behind the oven door)
IMPORTANT: Range must be level after installation. Follow 
the instructions in the “Level Range” section. Using the cooktop 
as a reference for leveling the range is not recommended.
 *  Range can be raised approximately 1" (2.5 cm) 
by adjusting the leveling legs.
**  Front of door and drawer may extend further forward 
depending on styling.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and 36" 
(91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, following the range hood or microwave 
hoods combination instructions for dimensional clearances 
above the cooktop surface.
A freestanding range may be installed next to combustible walls 
with zero clearance.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet 
is covered by not less than 
1
/
4
" (0.64 cm) flame retardant millboard 
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) 
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
A
B
D
F
E
C
A.  13" (33.0 cm) max. upper cabinet depth
B.  30" (76.2 cm) min. opening width
C.  For minimum clearance to top of cooktop, see NOTE*.
D.  30
1
/
8
" (76.5 cm) min opening width
E.  Outlet – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 
    5
1
/2" (14.0 cm) max. to floor
F.  Cabinet door or hinges should not extend into the cutout
Because Whirlpool Corporation includes a continues commitment to improve 
our products, we reserve the right to change materials and specifications 
without notice.
Dimensions are for planning purposes only. For complete details, 
see Installation Instructions packed with product. Specifications 
subject to change without notice.
Ref. W10403811C
8/3/15
30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an uncovered wood or metal cabinet.