Sub-Zero 700TCIX Informationshandbuch

Seite von 3
7017797
Integrated Column Star-K Kit
7017798 / Rev A / May, 2010
UPPER SECTION (DOOR) ALL 700 TALL UNITS:
1.
At the top of the units, extract upper switch box
mounting screws and flip the switch box over to
expose the wires (See Figure 1).
2.
Disconnect double yellow wire from the light switch
and both wires from the fan switch (See Figure 1).
3.
Make the following connections between the short
relay wire harness and cabinet wire harness  (See
Figure 2):
A. Male yellow relay harness wire to yellow 
cabinet wire.
B. Male black relay harness wire to purple or grey
or red cabinet wire, depending on unit.
NOTE:  When both fan wires are red, the black
relay harness wire must be connected to the
wire coming from the control board.
C. Male red relay harness wire to red cabinet wire.
NOTE:  When both fan wires are red, the red
relay harness wire must be connected to the
wire going to the fan motor.
D. Use the wire splice to connect the the white
relay harness wire to the free white 
cabinet wire.
4.
Make the following connections at the switches
(See Figure 2):
E. Female yellow relay harness wire to light switch.
F.
Female purple relay harness wire to fan switch.
G. Female red relay harness wire to fan switch.
G
D
A
E
F
B
C
Figure 1. Upper Switch Box
Figure 2. Wires to Connect
Page 1 of 3
CONTAINS:
QTY
DESCRIPTION
1
W/H, Star-K Assy. 700 Series
1
Bag, Zip-Lock 10 x 12
1
Diagram, 700Tall Star-K Wiring
SEVERE SHOCK HAZARD! DISCONNECT POWER TO UNIT BEFORE ATTEMPTING TO INSTALL
THESE COMPONENTS.
NOTE: For IC-27R and IC-27F units only.
Disconnect Double
Yellow Wire
Disconnect Both
wires at Fan Switch
Relay harness 
white wire
Free White
Neutral Wire
Free White 
Neutral Wire
QTY DESCRIPTION
1
Wire Splice, # 53440-2
1
Tape, Double-Sided Sided 1/2'' Wide
1
Instructions, Star-K 700Tall