Dacor ER36DCLP Installationsanweisungen

Seite von 24

Slide the end of the appliance cord into the strain relief from 
the bottom of the box
Connect the white (neutral) wire to the neutral terminal in the 
box.
Connect the L1 wire to the L1 power supply terminal in the 
box.
Connect the L2 wire to the L2 power supply terminal in the 
box.
If using a 4 Wire connection, connect the ground wire to the 
grounding screw inside the box.
Tighten the strain relief so that the appliance cord is held 
snuggly in place.
Replace the range electrical access cover.
5.
6.
7.
8.
9.
10.
11.
Electrical Connection (continued)
Connecting an Appliance Wire to the 
Range - Where Local Code Permits
 WARNING
Do not connect the green appliance wire to the neutral (white) 
supply wire unless local building codes permit.
Remove the range electrical access cover from the back of 
the range.
If using a 4 wire connection, loosen the grounding screw and 
remove the neutral to ground jumper link.
Remove the conduit bracket from the bottom of the range 
electrical box.
Disassemble and remove the strain relief from the appliance 
cord (not included). Insert  the tabs on the two parts of 
the strain relief into the hole on the bottom of the box and 
reassemble it so that the tabs are below the box and the 
strain relief itself is inside the box.
1.
2.
3.
4.
4 Wire Appliance 
Cord Connection
Strain Relief
L2 Wire
White Wire
Green Wire
Neutral Terminal
L1 Terminal
L2 Terminal
Jumper Removed
L1 Wire
Grounding Screw
14-50P Plug
Neutral
L2
L1
Ground
Strain Relief
Reassemble with tabs 
below and clamp above
Bottom of range electrical 
box
Remove conduit bracket 
before strain relief 
installation
Remove jumper on  
4 Wire installations
Electrical 
Access
Installation Instructions