Dacor ER48D Benutzung Und Pflege

Seite von 40
31
Before You Call for Service
Problem Solution Guide - Cooktop
Problem
May Be Caused By
What to Do
Igniters do not spark.
Power not supplied to unit.
Have electrician connect range to properly wired 
electrical connection.
Power to range is off.
Turn power on at junction box. Check for tripped 
circuit breaker or blown fuse.
Wet or dirty igniter.
Clean according to Care and Cleaning section.
Power outage.
Contact power company.
No flame.
Igniter not working (no clicking sound).
Clean according to Care and Cleaning section.
Wet or dirty igniter.
Clean and dry according to Care and Cleaning sec-
tion.
Gas is turned off.
Make sure the gas supply valve is in the on position.
Gas supply interrupted.
Contact gas company.
Flame is distorted, yellow or very 
large. 
Burner ring or burner cap is dirty or 
clogged.
Clean and dry according to Care and Cleaning sec-
tion.
Burner ring or burner cap not properly 
positioned.
Make sure burner is assembled according to the Set-
ting Up Your Range section.
Range set up to use a different type of 
gas (Natural or LP) or set up for differ-
ent altitude.
Have qualified service technician check to make sure 
that the range is set up for the type of gas and the 
correct altitude.
Gas regulator is not installed or faulty.
Have qualified service technician check the gas 
regulator.
Igniter continues to spark (click) 
after flame ignites.
Burner is cold.
Burners may continue to spark for up to 60 sec-
onds when cold and set to low. See Operating the 
Cooktop section for more information on how to 
minimize.
Flame distorted by air draft.
Minimize any air drafts around the range. Close 
nearby windows.
Wet or dirty igniter.
Clean and dry according to Care and Cleaning sec-
tion.
Burner ring or burner cap is dirty.
Clean and dry according to Care and Cleaning sec-
tion.
Burner ring or burner cap not properly 
positioned.
Make sure burner is assembled according to the Set-
ting Up Your Range section.
Flame goes out at low setting.
Air intake holes obstructed.
Check to make sure air holes above knobs are not 
blocked.
Low gas pressure.
Contact gas company.