VENTING   REQUIREMENTS
Determine which venting method is best for your application.  
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should 
be kept to a minimum to provide efficient performance.  The 
size of the ductwork should be uniform.  Do not install two el-
bows together.  Use duct tape to seal all joints in the ductwork 
system.  Use caulking to seal exterior wall or floor opening 
around the cap.
Flexible ductwork is not recommended.  Flexible ductwork 
creates  back  pressure  and  air  turbulence  that  greatly 
reduces performance.
Make sure there is proper clearance within the wall or floor for 
exhaust duct before making cutouts.  Do not cut a joist or stud 
unless absolutely necessary.  If a joist or stud must be cut, then 
a supporting frame must be constructed. 
FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 
TO PAGE 4.
WARNING - To Reduce The Risk Of Fire, Use Only Metal 
Ductwork.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a 
separate 15 amp fused circuit.  A time-delay fuse or circuit 
breaker is recommended.  The fuse must be sized per local 
codes in accordance with the electrical rating of this unit as 
specified on the serial/rating plate located inside the unit near the 
field wiring compartment.  THIS UNIT MUST BE CONNECTED 
WITH COPPER WIRE ONLY.  Wire sizes must conform to the 
requirements of the National Electrical Code, ANSI/NFPA 70 
- latest edition, and all local codes and ordinances.  Wire size 
and connections must conform with the rating of the appliance.  
Copies of the standard listed above may be obtained from: 
 
National Fire Protection Association
 
Batterymarch Park
 
Quincy, Massachusetts  02269
• Venting system MUST terminate outside the 
home.
• DO NOT terminate the ductwork in an attic or 
other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the flow of combustion and 
ventilation air.
• Failure to follow venting requirements may result 
in a  fire.
This appliance should be connected directly to the fused discon-
nect (or circuit breaker) through flexible, armored or nonmetallic 
sheathed copper cable.  Allow some slack in the cable so the 
appliance can be moved if servicing is ever necessary.  A UL 
Listed, 1/2" conduit connector must be provided at each end 
of the power supply cable (at the appliance and at the junction 
box).
When making the electrical connection, cut a 1   1/4" hole in the 
wall.  A hole cut through wood must be sanded until smooth.  A 
hole through metal must have a grommet. 
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, do not use this fan with any solid-state speed 
control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:  Use this unit only in the manner intended 
by the manufacturer.  If you have any questions, contact 
the manufacturer.
Before  servicing  or  cleaning  unit,  switch  power  off  at 
service panel and lock the service disconnecting means 
to  prevent  power  from  being  switched  on  accidentally.  
When the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, 
to the service panel.
CAUTION: For General Ventilating Use Only.  Do Not Use To 
Exhaust Hazardous  or  Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: Installation Work And Electrical Wiring Must 
Be Done By Qualified Person(s) In Accordance With All 
Applicable  Codes  And  Standards,  Including  Fire-Rated 
Construction.  
Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning 
equipment  to  prevent  backdrafting.    Follow  the  heating 
equipment manufacturer's guideline and safety standards 
such as those published by the National Fire Protection 
Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), 
and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
   WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, 
nonmetallic gaskets or other materials, DO NOT 
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding 
circuit.  A fuse in the neutral or grounding circuit 
could result in electrical shock.
• Check with a qualified electrician if you are in doubt 
as to whether the rangehood is properly grounded. 
• Failure to follow electrical requirements may result 
in a fire.   
   WARNING
For residential use only.
!
!
Cold Weather installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a nonmetallic thermal break should 
be installed to minimize conduction of outside temperatures 
as part of the vent system. The damper should be on the cold 
air side of the thermal break. The break should be as close as 
possible to where the vent system enters the heated portion 
of the house.