model-specIfIc btu outputs
model
H burner
rotIsserIe
prosear
total Input
l27(f)
2 @ 25,000 btu
50,000 btu/Hr
l27(f)r
2 @ 25,000 btu
1 @ 14,000
64,000 btu/Hr
l27ps(f)r
1 @ 25,000 btu
1 @ 14,000
1 @ 23,000
62,000 btu/Hr
l30r(f)
2 @ 25,000
1 @ 14,000
64,000 btu/Hr
l30ps(f)r
1 @ 25,000
1 @ 14,000
1 @ 23,000
62,000 btu/Hr
l36r
3 @ 25,000
1 @ 14,000
89,000 btu/Hr
l36ps(f)r
2 @ 25,000
1 @ 14,000
1 @ 23,000
87,000 btu/Hr
l42r
3 @ 25,000
1 @ 16,000
91,000 btu/Hr
l42ps(f)r
2 @ 25,000
1 @ 16,000
1 @ 23,000
89,000 btu/Hr
l54ps(f)r
3 @ 25,000
2 @ 14,000
1 @ 23,000
126,000 btu/Hr
maxImum runs for all
applIances on supply lIne
Run length
3/4” pipe
(in feet)
max Btu for all
appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135.000
70
123,000
80
115,000