COYOTE CPB Handbuch

Seite von 22
 
 
 
17 
gap between the electrode and contact point.   
• 
Check for a loose wire connection at the electrode box. 
• 
Check to see if debris is blocking the electrodes. 
• 
If the igniter is not working, can you light the power burner with 
a lighter? 
Flare-ups
 
• 
Check frame body and cooking grate for excess food or 
grease build-up. 
• 
Ensure power burner is not placed directly in the path of wind. 
• 
Be sure drip tray is clean 
Note: Some flare-ups may be inevitable if cooking greasy 
foods. 
Yellow Flames   
• 
Check the burner inlet for obstructions, particularly at air inlets 
for each burner. 
• 
Power burner may be in an area that is too windy.
 
• 
Ensure correct gas supply is being used with correct appliance 
type (LP / NG)
 
Flame  blows  out  on  low  setting 
or has uneven heat distribution. 
• 
Check  for  spider  webs  or  insect  nest  in  venturi  and  clean 
venturi. 
• 
Venturi  may  be  misaligned  and  needs  to  be  lined  up  over 
orifices. 
• 
Windy  weather  will  require  you  to  move  power  burner  away 
from the wind. 
• 
Lack of fuel. Check to see cylinder valve is open and cylinder 
has fuel.
 
Low  heat  with  the  knob  on 
“HIGH” 
• 
Check to see if the fuel hose is bent or kinked. 
• 
Make sure the power burner area is clear of dust. 
• 
Check your gas supply and gas pressure.   
• 
If it is only one burner that appears low, make sure the orifice 
or burner is clean. 
Power burner is Too Hot 
• 
Excess grease build-up causing grease fires. 
• 
Damaged or faulty regulator. 
• 
Replace with factory authorized parts.
 
• 
Cook on a lower temperature setting.
 
Flame  behind  control  panel  or 
control knob area. 
IMMEDIATELY shut off cylinder valve and allow power burner 
to cool. 
• 
C
heck  for  spider  webs  or  insect  nest  in  venturi  and  clean 
venturi. 
• 
Gas  is  leaking  from  a  faulty  connection.  Tighten  connections 
with  an  adjustable  wrench  and  replace  damaged  parts. 
Perform  a  leak  test  on  all  connections  before  cooking  on 
power burner again. 
• 
Venturi  may  be  misaligned  and  needs  to  be  lined  up  over 
orifice.
 
Fire at any connection. 
IMMEDIATELY shut off cylinder valve and allow power burner 
to cool. 
• 
Gas  is  leaking  from  a  faulty  connection.  Tighten  connections 
with an adjustable wrench and replace damaged parts. 
• 
Perform  a  leak  test  on  all  connections  before  cooking  on 
power burner again.