Sub-Zero 700TCILH Installationsanleitung

Seite von 20
3
Dimensions in parentheses are in
millimeters unless otherwise specified.
T O O L S A N D M A T E R I A L S R E Q U I R E D
The following is a list of tools and materials
that should be available for proper installation.
Phillips screwdriver set
Slotted screwdriver set
4' (1.2 m) of
1
/
4
" copper tubing and saddle
valve for the water line—part #4200880
(do not use self-piercing valves)
Copper tubing cutter
Level—2' (.6 m) and 4' (1.2 m)
recommended
Appliance dolly able to support 500 lbs
(227 kg) and adequate help to handle the
weight of the unit
Various sized pliers
Wrench set
Allen wrench set
5
/
16
" hex bolt nut driver
Crescent wrenches
Drill and assorted drill bits
Masonite, plywood,
1
/
8
" pressed fiberboard,
cardboard or other suitable material to
protect finished flooring
Appropriate materials to cover and protect
the home and its furnishings during
installation
I N S TA L L AT I O N
R E C O M M E N D A T I O N S
The importance of the installation of the
Sub-Zero Integrated unit cannot be overem-
phasized. Installation should be done by a
qualified installer.
Before you begin the installation process,
it is recommended that you read this entire
Installation Instructions book. There are key
details that you should take special care to
observe during the installation. By reading
these instructions carefully, you will make the
installation process easier, problem-free and,
most importantly, safe.
Any questions or problems about the
installation should be directed to your
Sub-Zero dealer or the Sub-Zero Customer
Service Department at 800-222-7820. You can
also visit our website at subzero.com.
S I T E P R E P A R A T I O N
Make sure that the finished rough opening
where the Integrated unit is to be installed is
properly prepared. Refer to the Overall
Dimensions and Installation illustrations for
your specific model on the following pages.
Make sure that the rough opening dimensions,
door and drawer clearances, electrical service
and plumbing are correct for the model you
are about to install.
Be sure that the plumber, electrician and
cabinet installer have this information before
finishing work is completed.
IMPORTANT NOTE: The inside edges of the
rough opening, as well as the sides and a
portion of the backside of the decorative
panels will need to be finished, as they will be
exposed when the doors are open.
I N T E G R AT E D