Total height of the cupboard (i.e. 70-3/8 in. (1788 mm))
plus  thickness  of  the  cover  and  floor  plate  (normally
3/4 in. (19 mm)) minus the height of the freezer cabinet
door  leaf  (xxx  in.  (xxx  mm))  as  calculated  above  and
minus  the  gap  width  (approximately  1/8  in.  (3  mm)):
70-3/8 in. + 3/4 in. + 3/4 in. - xxx in. - 1/8 in. = 71-3/4 in.
- xxx in. ( 1788 mm + 19 mm + 19 mm - xxx mm - 3 mm
= 1823 mm - xxx mm )
7 Air circulation in the kitchen
cabinet
Fig. 4 
Fig. 5 
- There  must  be  an  effective  ventilation  gap  of  at  least
31 in
2
 (200 cm
2
) per appliance for the air inlet
 Fig. 5 (A)
and the air outlet
 Fig. 5 (B)
.
- Basically,  the  bigger  the  ventilation  gap,  the  more
energy-saving the operation of the appliance.
- The  depth  of  the  ventilation  shaft  on  the  back  wall  of
the cabinet must be at least 1-1/2 in. (40 mm).
Fig. 6 
- The  top  ventilation  gap  can  be  set  up  either  directly
above  the  appliance  with  an  optional  ventilation  grid
Fig. 6 (C)
 near the ceiling, above the cabinet
 Fig. 6 (D)
 or
as an air vent in a false ceiling
 Fig. 6 (E)
.
Air circulation in the kitchen cabinet
* Depending on model and options
7