Vent-a-Hood PRH18130SS Spezifikationenblatt

Seite von 1












VP562/VP563
transition 
centers outlet 
over top of hood
WALL MOUNT RANGE HOOD SPECIFICATIONS
*Recommended mounting 
height is for optimum 
performance.
Connection Diagram (42” - 60" Widths)
Connection Diagram (48” - 66" Widths) 
900 CFM B200 Dual & B100 Single Blower
(Top View)
1200 CFM Double B200 Dual Blowers
(Top View)
6” Outlet
Vent
Hole
3 ¼”
Electrical
Centerline
of Hood
Wall Side
1 ¾”
1 3⁄8”
5 ¼”
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”
5 ½”
Wall Side
8” Outlet
6” Outlet
5 ¼”
Wall Side
Vent
Holes
Centerline
of Hood
Electrical (2)
5 ½”
7 5⁄16”
1 7⁄8”
7 5⁄16”
1 ¾”
11”
11”
5 ½”
5 ½”
Wall Side
5 ¼”
1 ¾”
Electrical (2)
8” Outlet
Vent
Holes
8” Outlet
Centerline
of Hood
10” Round
10” Round
8” Round
17 ½”
2”
8” Round
6” Round
12” Round
12” Round
16 ½”
8” Round
8” Round
8” Round
3”
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Connection Diagrams (30” - 48” Widths)
Recommended
Mounting Height*
UL
C
US
R
10” OR 12”
Round
300 CFM B100 Single Blower
(Top View)
600 CFM B200 Dual Blower
(Top View)
NPH18/NPXH18/PRH18/PRXH18/SLH18/SLXH18  Equipped with halogen lighting. WBAR warming 
light bar is available on selected models. X in part number indicates 27” depth.
NPH18/NPXH18
PRH18/PRXH18
SLH18/SLXH18
Electrical/Mechanical Specifications For Blower Units
Model
Volts
Amps*
Hz
RPM
CFM
SP@0.0" Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single
115
1.5
60
1550
300
450
273
245
225
6" (28 in.
2
)
5.4
B200 Dual
115
2.9
60
1550
600
900
531
480
430
8" (50 in.
2
)
6.5
B200 Dual & B100 Single
115
4.4
60
1550
900
1350
804
725
655
VP562: 10" (79 in.
2
)
6.3
Two B200 Duals
115
5.8
60
1550
1200
1800
1062
960
860
VP563: 12" (113 in.
2
)
6.6
*  Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
•  Because the Magic Lung
®
blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung
®
 blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more 
efficiently than other than other filtration systems. When comparing the Magic Lung
®
with other blower units made by other manufacturers, use the “Equivalent CFM”.
#  Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0813A






