SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes. 
The electrical supply must be located within the shaded 
area shown in the illustration and chart below. A separate 
circuit, servicing only this appliance is required. A ground 
fault circuit interrupter (GFCI) is not recommended and may 
cause interruption of operation.
The electrical outlet must be positioned with the grounding 
prong to the right of the thinner blades.
 CAUTION
The outlet must be checked by a qualified electrician to 
be sure that it is wired with the correct polarity. Verify 
that the outlet is properly grounded.
 WARNING
Do not use an extension cord, two-prong adapter or 
remove the power cord ground prong.
ELECTRICAL REQUIREMENTS
Electrical Supply 
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
WIDTH
A
18" Models
6"
 (152)
24" Models
9
1
/
2
"
 (241)
27" Models
11"
 (279)
30" Models
12
1
/
2
"
 (318)
36" Models
15
1
/
2
"
 (394)
Plumbing
Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded 
area shown in the illustration below. The water supply line 
should be connected to the house supply with an easily 
accessible shut-off valve. Do not use self-piercing valves. 
The water supply line must be flush to the floor and not 
interfere with installation of the anti-tip bracket.
Column and tall models with an ice maker or water dis-
penser feature a water filtration system. An in-line filter is 
required for drawer models with an ice maker when water 
conditions have a high sediment content.
A reverse osmosis system can be used provided there is 
constant water pressure of 35–120 psi
 (2.4–8.3 bar)
 supplied 
to the unit at all times. In this application, the water filtra-
tion system must be bypassed. Refer to water filter bypass 
on page 15. A copper line is not recommended for this 
application.
PLUMBING REQUIREMENTS
Water Supply Line 
1
/
4
" OD copper, braided 
stainless steel or PEX tubing
Water Pressure
35–120 psi
 (2.4–8.3 bar)
Excess Water Line for Connection
36"
 (914)
 
WATER SUPPLY LOCATION
WIDTH
A
18" Models
3"
 (76)
24" Models
5
1
/
2
"
 (140)
30" Models
6"
 (152)
36" Models
9"
 (229)
A
1
/
4
(6)
1
/
4
(6)
4
1
/
4
"
(108)
4
1
/
2
"
(114)
FLOOR
LEFT SIDE
OF OPENING
 
Electrical supply location.
 
3" 
(76)
6" 
(152)
RIGHT SIDE
OF OPENING
AREA EXTENDS 1
/
2
"
 (13)
FORWARD ON FLOOR
A
 
Water supply location.