Broan APE130SS Installationsanweisungen

Seite von 16
APE1  SERIES
Page 3
PREPARE THE HOOD
4
Blower is shipped in Vertical Discharge Position.
To change blower to
Horizontal Discharge Position:
Remove
Knurled  Nuts  from  Blower  Mounting  Rods.
Disengage mounting rods from blower and rotate blower
to  horizontal  discharge  position.  Re-engage  mounting
rods and tighten blower in place with knurled nuts.
3
Remove  the
Aluminum  Filters,  Bottom  Cover,  and
Wiring Cover from the hood.
ALUMINUM
FILTERS
BOTTOM
COVER
WIRING
COVER
VERTICAL DISCHARGE POSITION
HORIZONTAL DISCHARGE POSITION
BLOWER
MOUNTING
ROD (2)
KNURLED NUT (2)
BLOWER
MOUNTING
ROD (2)
KNURLED NUT (2)
BLOWER
BLOWER
5
Remove
Vertical Duct Knockout or Horizontal Duct 
Knockout and attach Damper / Duct Connector with
two (2) screws (supplied).
VERTICAL DUCT
KNOCKOUT
HORIZONTAL DUCT
KNOCKOUT
DAMPER /
DUCT
CONNECTOR
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent  
power from being switched on accidentally.
6
Run
House  Power  Cable  between  service  panel  and
hood location. Attach power cable to hood using appropri-
ate connector.
7
Hold  the  hood  in  position  under  the  cabinet.  Make  sure
the  damper  /  duct  connector  enters  the
Ductwork  and
that the damper opens and closes freely.
8
Tighten the four (4)
Mounting Screws completely to se-
cure the hood to the cabinet.
HOUSE
POWER
CABLE
MOUNTING
SCREWS (4)
DUCTWORK