Installation Specifications
 WARNING
•  This appliance must be installed and electrically 
grounded in conformance to local codes.
•  In the absence of local codes, the appliance 
installation must conform with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 and the National 
Electrical Code, ANSI/NFPA 70.
•  Installation of this range in a manufactured (mobile) 
home must conform with the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 
3280 [formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD (Part 280)] or 
with local codes where applicable.
•  This range is not designed for installation in a 
recreational vehicle.
•  Do not obstruct flow of combustion and ventilation air.
•  To prevent an electric shock hazard, the power supply 
must meet the specifications stated below. It is the 
owner’s responsibility to make sure that the electrical 
service meets electrical requirements and that the 
electrical outlet has been properly installed by a 
licensed electrician.
Electrical Power Supply Requirements
•  The range is supplied with a factory installed, 6 foot 
long, power cord with a three-prong grounding plug. 
It is connected to the chassis at the rear of the range. 
It must be connected to a dedicated, grounded three-
prong electrical outlet installed by a licensed electrician.
•  The correct voltage, frequency and amperage must 
be supplied to the electrical outlet according to the 
product data label (see inside cover for location). The 
Electrical Supply Requirements provided below are 
for reference.
Electrical Circuit 
Required
Total Connected Load
120 Vac 60 Hz,  
15 Amp.
0.5 kW 
(4.0 Amp.)
Electrical Supply Requirements
IMPORTANT: The above information is for reference only. 
If the information above differs from the information on the 
product data label on the appliance, use the information on 
the label.
Gas Supply Requirements
•  Be certain that the range being installed is correct for 
the gas service being provided (natural gas or LP gas). 
•  An external manual shut-off valve must be installed 
between the gas inlet and the range for the purpose of 
turning on or shutting off gas to the appliance.
•  The range comes from the factory with the regulator 
installed. Use only the installed regulator. 
•  The gas inlet on the regulator accommodates a 
1/2” NPT gas line connection. The range can also 
accommodate a 3/4” NPT gas line connection by 
removing the 1/2” to 3/4” adapter on the regulator inlet.
Gas 
Type
Manifold 
Pressure* 
(WC)
Min. Gas Supply 
Pressure (WC)
Max. Input 
Pressure
Natural
5”
6”
1/2 psi
LP
10”
11”
1/2 psi
Gas Supply Requirements
* The gas supply pressure for testing the regulator setting 
shall be at least 1 inch water column (249 Pa) above the 
specified manifold pressure.
IMPORTANT: The information above is for reference only. If 
the above data does not agree with the product data label, 
use the data on the label. See the inside cover for location.
The gas connection is located on the back of the unit as 
shown below.
12 1/4”
(31.1 cm)
to
14 1/4”
(36.2 cm)
4 1/4”
(10.8 cm)
Power 
cord
Gas 
connection