Wolf PL521912 Installationsanleitung
MODEL 804701
Page 3
OUTSIDE - ROOF VIEW
OUTSIDE - WALL VIEW
10 Cover
Screws
10 Cover
Screws
Bird Screen
Flashing
Sheet
Drill 6
Mounting
Holes
Damper
25"
29½"
14
11
/
16
"
14
5
/
8
"
W
all Stud
W
all Stud
11" dia.
hole
20"
1¼" dia. hole
3"
REMOVE
SIDING
Pilot Hole
(centered between studs)
WALL MOUNT
INSTALLATION
For use with Models CTWH30, CTWH36, IH4227, W30-662418, W30-662718, I36-663418,
L34-582212, DD30R, DD36R, DD45R.
PREPARE THE WALL
WIRE THE VENTILATOR
From inside the wall:
1
Drill a
PILOT HOLE through the wall, centered between
WALL STUDS.
From outside - on the wall:
2
Measure and mark the 25" x 29½" rectangle. Cut and remove
only the siding inside this rectangle.
3
Measure and mark the
11" DIAMETER HOLE and the 1¼"
DIAMETER HOLE. Cut these holes all the way through the
wall.
BLACK TO BLUE
WHITE
TO
BROWN
120
VAC
LINE
IN
GROUND
TO
GROUNDING
SCREW
INSTALL THE VENTILATOR
4
Remove
10
COVER SCREWS
and lift off
ventilator cover.
5
Feed the electric
power cable
through the
1¼"
DIAMETER HOLE
and connect cable
to ventilator with a
proper connector
for the type of
cable being used.
6
Connect
BLACK
TO BLACK,
WHITE TO BLUE,
and
GROUND
TO GROUNDING
SCREW.
7
Place ventilator on wall so that ventilator's discharge collar
fits into 11" diameter hole.
8
Use the 6 screws (provided) to attach the ventilator to the
wall.
DRILL 6 MOUNTING HOLES inside the ventilator, as
necessary.
9
Seal the screw heads and edges of the flashing sheet with
a good grade of roofing cement.
10
Check for free movement of the spring-loaded
DAMPER
and re-install ventilator cover. Turn on power and check
operation.
WHITE
TO
BLUE
BLACK TO BLACK