Wolf PL521912 Installationsanleitung

Seite von 38
MODEL 804701
Page 3
OUTSIDE - ROOF VIEW
OUTSIDE - WALL VIEW
10 Cover 
Screws
10 Cover 
Screws
Bird Screen
Flashing
Sheet
Drill 6 
Mounting 
Holes
Damper
25"
29½"
14
11
/
16
"
14 
5
8
"
W
all Stud
W
all Stud
11" dia.
hole
20"
1¼" dia. hole
3"
REMOVE
SIDING
Pilot Hole
(centered between studs)
 
WALL MOUNT
  INSTALLATION
For use with Models CTWH30, CTWH36, IH4227, W30-662418, W30-662718, I36-663418, 
L34-582212, DD30R, DD36R, DD45R.
PREPARE THE WALL
WIRE THE VENTILATOR
From inside the wall:
1
  Drill a 
PILOT HOLE through the wall, centered between 
WALL STUDS.
From outside - on the wall:
2
  Measure and mark the 25" x 29½" rectangle. Cut and remove 
only the siding inside this rectangle.
3
  Measure and mark the 
11" DIAMETER HOLE and the 1¼" 
DIAMETER HOLE. Cut these holes all the way through the 
wall.
BLACK TO BLUE
WHITE
TO
BROWN
120 
VAC
LINE
IN
GROUND
TO
GROUNDING
SCREW
INSTALL THE VENTILATOR
4
 Remove 
10 
COVER SCREWS 
and lift off 
ventilator cover.
5
  Feed the electric 
power cable 
through the 
1¼" 
DIAMETER HOLE 
and connect cable 
to ventilator with a 
proper connector 
for the type of 
cable being used.
Connect 
BLACK 
TO BLACK
WHITE TO BLUE
and 
GROUND 
TO GROUNDING 
SCREW.
7
  Place ventilator on wall so that ventilator's discharge collar 
fits into 11" diameter hole.
8
  Use the 6 screws (provided) to attach the ventilator to the 
wall. 
DRILL 6 MOUNTING HOLES inside the ventilator, as 
necessary.
9
  Seal the screw heads and edges of the flashing sheet with 
a good grade of roofing cement.
10
  Check for free movement of the spring-loaded 
DAMPER 
and re-install ventilator cover. Turn on power and check 
operation.
WHITE
TO
BLUE
BLACK TO BLACK