Broan QSE130WW Installationsanleitung
Page 3
ALLURE
®
QSE1 SERIES
RANGE HOOD
PREPARE THE HOOD
5
Remove either top or back wiring knockout and install ap-
proved
Electrical Cable Clamp.
ELECTRICAL
CABLE CLAMP
6
Remove appropriate
Duct Knockout(s) from top or back of
hood.
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Horizontal Discharge)
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical Discharge)
7
3¼” x 10” Ducted Discharge Only: Attach
Damper/Duct
Connector over knockout opening. Make sure damper Pivot
is nearest to
Top/Back Edge of hood. Remove Tape from
damper flap.
DAMPER/DUCT
CONNECTOR
(Vertical discharge
position shown)
TAPE
NOTE
Damper/Duct Connector can be installed up to 1-inch
on either side of hood center to accomodate off-center
ductwork. In extreme off-center installations, one end
of the duct connector may need to be trimmed to clear
the electrical cable clamp.
TOP/BACK
EDGE
UP TO 1”
SIDE-TO-SIDE
ADJUSTMENT
ADJUSTMENT
PIVOT
Ú
Ù
PREPARE THE HOOD
3
Remove
Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts
bag.
DAMPER/DUCT
CONNECTOR
4
Remove
Wiring Cover from inside the hood. Set cover
and mounting screw aside.
WIRING
COVER