DRYER DIMENSIONS
23
3
/
8
"
(594 mm)
33
1
/
4
"
(845 mm)
23
1
/
4
"
(603 mm)
39"
(991 mm)
Back view:
3
1
/
4
"
(83 mm)
11
3
/
4
"
(299 mm)
27"
(686 mm)
NOTE: Most installations 
require a minimum of 
5" (127 mm) clearance 
behind dryer for exhaust 
vent with elbow. See 
“Venting Requirements.”
LOCATION REQUIREMENTS
Check code requirements. Some codes limit, or do not permit, 
installing dryer in garages, closets, mobile homes, or sleeping 
quarters. Contact your local building inspector.
You will need:
n
   A location allowing for proper exhaust installation.  
See “Venting Requirements.”
n
   A separate 30 amp circuit.
n
   If using power supply cord, a grounded electrical outlet  
located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
n
   Floor must support dryer weight of 115 lbs. (52 kg).  
Also consider weight of companion appliance.
n
   Level floor with maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), install Extended  
Dryer Feet Kit, Part Number 279810. If not level, clothes  
may not tumble properly and automatic sensor cycles may  
not operate correctly.
n
   For garage installation, place dryer at least 18" (460 mm) 
above floor. If using a pedestal, you will need 18" (460 mm) 
to bottom of dryer.
n
   The dryer must not be installed or stored in an area where  
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where  
it will be exposed to water, weather, or at temperatures below  
45° F (7° C). Lower temperatures may cause dryer not to  
shut off at end of sensor cycles, resulting in longer drying times.
Installation Clearances
For each arrangement, consider allowing more space for ease  
of installation and servicing, spacing for companion appliances,  
and clearances for walls, doors, and floor moldings. Space  
must be large enough to allow door to fully open. Add spacing  
on all sides of dryer to reduce noise transfer. If a closet door  
or louvered door is installed, top and bottom air openings  
in door are required.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Side view:
Front view:
Power supply 
cord/cable
Vent