Extended Height Grille
 
6
Specify the customer-supplied hinging system consistent 
with cabinetry and with sufficient capacity for the weight 
of the decorative grille panel.
IMPORTANT NOTE: In the event that refrigeration com-
ponents must be removed for service, the standard grille 
frame will need to be removed first for sufficient access to 
the machine compartment. To avoid an unsupported load, 
the decorative panel will need to be removed from the 
cabinetry first. 
Grille Hinging System
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN CLOSED
POSITION
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN FULLY
RAISED POSITION
GRILLE CLEARANCE
REQUIRED FOR SERVICE
CLEAT
CLEAT END VIEW
1
/
2
(13)
2" 
(51)
1
1
/
2
"
(38)
1
/
2
(13) LIP
2" 
(51)
1
1
/
2
"
(38)
Field install a cleat to the back side of the decorative grille 
panel to hold the flip-up inner grille frame in position when 
it is raised. Follow dimensions in the inset illustration for 
the 10"
 (254)
 long cleat. For location of the cleat, also refer 
to the illustration on the following page.
For a dual installation, use two cleats.
  HINGING SYSTEM—INSTALL CLEAT
SIDE VIEW
The cleat must include a lip as shown, to prevent 
unintentional separation of decorative grille panel and 
grill frame.