Connecting the appliance
After installing the appliance, wait at least 1 hour until 
the appliance starts up. During transportation the oil in 
the compressor may have flowed into the refrigeration 
system.
Before switching on the appliance for the first time, 
clean the interior of the appliance (see chapter 
“Cleaning the appliance”).
Water connection
,
CAUTION: 
Connect the appliance to a drinking water line.
The water may be connected only by a competent fitter 
according to the local regulations of the appropriate 
water supply company.
A cold water connection is necessary for operating 
the automatic ice maker. The water pressure must be 
between 25 and 120 p.s.i. (1,72 and 8,25 bar). The 
installation must correspond to the local plumbing 
regulations.
A separate shut-off valve should be installed in 
the cold-water inflow.
The shut-off valve should not be located behind 
the appliance. It is recommended that you mount 
the shut-off valve directly next to the appliance or at 
another place which is easily accessible.
When installing the water connection, pay attention to 
the permissible installation area for the water mains.
For connection to the drinking water mains use only 
water pipes which are suitable for drinking water. 
Observe national regulations and the connection 
conditions of the local water supply companies.
Electrical connection
,
WARNING: 
Avoid the risk of an electric shock!
,
WARNING: 
Insert into a grounded 3-phase socket. Never 
remove grounding phase. Do not use any 
adapters. Do not use any extension cables.
,
WARNING: 
Non-compliance with these instructions may 
result in death, fire or an electric shock. 
Improper connection of the protective conductor 
may result in an electric shock. If you are in 
doubt whether the appliance has been grounded 
properly, have the appliance tested by 
a qualified electrician or service technician.
The socket must be near the appliance and also freely 
accessible following installation of the appliance.
The appliance complies with protection class I. 
Connect the appliance to 115 V/60 Hz alternating 
current via a correctly installed socket with protective 
conductor. The socket must be fused with a 10 to 16 A 
fuse.
The appliance comes with a UL registered 3-wire power 
cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:
Check on the rating plate whether the indicated voltage 
and current type correspond with the values of your 
power supply. The location of the rating plate can be 
found in the chapter entitled Customer service.
,
WARNING: 
Never connect the appliance to electronic 
energy saver plugs.
Our appliances can be used with mains and 
sine-controlled inverters. Mains-controlled 
inverters are used for photovoltaic systems 
which are connected directly to the national grid. 
Sine-controlled inverters must be used for 
isolated applications (e.g. on ships or 
in mountain lodges) which are not connected 
directly to the national grid.
Appliance
Maximum simulta-
neous load
Fridge-
freezer
6.0 amps