Thermador PH36GS Installationsanweisungen

Seite von 50
English 14
Wiring the Hood with an Inline 
Blower
1.
Remove the junction box cover.
2.
Install 1/2” (13mm) conduit connectors.
3.
Run black, white, and green wires (#12 AWG) in 1/2” 
(13mm) conduit from power supply to junction box.
4.
Connect the power supply wires to the hood wires in 
the following order: black to black, white to white, and 
green wire to green ground screw on chassis. Use 
spring type wire nuts supplied. (Lost or missing wire 
nuts should only be replaced with: Spring type wire 
nuts, rated for a minimum of (2) # 18ga wires and 
maximum of (4) #14ga wires, UL & CSA rated to 600V 
and 302° F/ 150° C).
5.
Connect the “pigtail” to the connector inside the 
junction box.
6.
Run (5) wires (#14 AWG) in 1/2” (13mm) conduit from 
the inline blower to the second conduit connector. 
7.
Connect the inline blower to the pigtail wires (Step 6) 
as per Figure 23. Connect the inline blower green 
(ground) wire to the ground screw in the junction box.
8.
Close junction box cover. Check that all light bulbs are 
secure in their sockets. Install filters (“Installing Filters, 
Grease Trays, and Heat Lamps” on page 15). Turn 
power on at service panel, and check lights and blower 
operation per Use & Care Manual. 
 Figure 22: Inline Blower
 Figure 23: Wiring the Hood with an Inline Blower
12
7
/
8
(327mm)
9
7
/
8
(251mm)
12
7
/
8
(327mm)
14
3
/
8
(365mm)
12”
(305mm)
19
1
/
8
(486mm)
7
/
8
“(22mm)
 
7
/
8
(22mm)