Dacor ETT3652B Installationsanleitung

Seite von 8
2
Verifying the Package Contents
Please contact your dealer immediately if 
components are missing.
•  Use and Care Manual
•  Mounting Brackets
•  Cleaning Creme
•  Glass Scraper
•  Foam Tape
Power Disconnection
 
WARNING: 
Failure to disconnect power may 
result in electrical shock or fire 
hazard! If the electric service 
provided does not meet the 
product specifications, do not 
proceed with the installation. Call 
the selling dealer or a licensed 
electrician
Electrical Power Supply 
Requirements
It is the owner’s responsibility to ensure that 
the electrical connection of this appliance 
is performed by a qualified electrician. The 
electrical installation, including minimum supply 
wire size and grounding, must be in accordance 
with the National Electric code ANSI/NFPA 70-
1993* (or latest revision) and local codes and 
ordinances. 
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage 
must be supplied to the appliance from a 
separate, grounded, circuit that is protected by a 
properly sized circuit breaker or time delay fuse. 
Refer to the data plate located on the bottom 
of the chassis, and/or to Table 1 below, for 
electrical supply requirements. 
Model No.
Electrical Circuit Required
Total Connected 
Load
Minimum Supply Wire Size
Line and Ground Connections
CER304
240VAC, 60Hz, 40A
6.9kW (29A)
No. 8 AWG
208VAC, 60Hz, 40A
6.9kW (33A)
CERB365
240VAC, 60Hz, 50A
9.6kW (40A)
208VAC, 60Hz, 50A
9.6kW (46A)
ETT304
240VAC, 60Hz, 30A
6.9kW (29A)
ETT365
240VAC, 60Hz, 40A
8.9kW (37A)
ETT365S
MET304
6.9kW (29A)
METB365
240VAC, 60Hz, 50A
9.6kW (40A)
 Electrical Supply Requirments
Countertop Preparation 
WARNINGS:
1.  To reduce the risk of personal 
injury caused by reaching 
over a hot appliance, cabinet 
storage space located directly 
above the cooktop should be 
avoided.
2.  Do not store combustible 
materials or items adversely 
affected by heat in cabinet 
areas above the appliance.
3.  Failure to provide proper 
clearances may result in a fire 
hazard!
 
NOTES:
1.  If cabinet storage space is to 
be provided directly above the 
cooktop, the risk of personal 
injury may be reduced by 
installing a ventilating hood 
that projects horizontally a 
minimum of 5 inches beyond 
the face of the cabinets.
2.  Allow a minimum 2-inch 
clearance between the bottom 
of the cooktop chassis and 
any combustible surface, 
including the upper edge of 
a drawer installed below the 
cooktop.
3.  Access to the underside of 
the cooktop and the junction 
box must be provided for 
inspection and service.
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
28 1/2" (724mm)
2" (51mm)
21" (533mm)
30" (762mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
2 1/4"
(57mm)
Min.
19 7/8" (505mm)
25" (635mm)
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
34 1/2" (876mm)
2"
(51mm)
25" (635mm)
21"
(533mm)
36" (914mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
19 7/8" (505mm)
2 1/4"
(57mm)
Min.
Cutout Dimensions for the CER304, ETT304, and MET304
(CER304 shown)
Cutout Dimensions for the CERB365, ETT365, ETT365S, and METB365
(ETT365 shown)