Dacor ER30GISCHLP Designanleitung

Seite von 3
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.5
30” Wide, Epicure
®
All Gas Range
ER30G, ER30GI
 WARnInG
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information. 
This appliance must be installed in accordance with the 
accompanying installation instructions.
All tolerances ±1/16” (±1.6mm) unless otherwise noted.
1 1/8” (29mm)
1 9/16”
(40mm)
2” (51mm)
3” (76mm)
Front of open door
Front of handle
Front edge of bullnose
Front panel
Rear of front panel
Backguard thickness
26 1/8” (664mm)
27 1/16” (687mm)
28 9/16” (725mm)
24” (610mm)
3” (76mm)
Backguard***
ER30G:
Full stainless 
steel side panels
ER30GI:
Partial stainless 
steel side panel
Grates extend
1” above trim
6” (152mm)
Backguard*
1 3/4” (44mm) Backguard**
***
**
*
Optional on both models, 
NOT  
compatible with self-rimming installations
Standard on model ER30G
Optional on model ER30GI, 
NOT
compatible with self-rimming installations 
Standard on model ER30GI
Optional on model ER30G 
Product width:
29 7/8” (759mm) 
ER30G is designed for freestanding install-
ations. ER30GI is designed for installation 
in a recessed cabinet or island. ER30G is 
NOT equipped for self-rimming installation.
NOTE: Neither model is 
compatible with a raised vent.
35”
(889mm)
to
37 1/8”
(943mm)
9” (229mm)
Backguard***
45 9/16” (1157mm)
ER30G/ER30GI 
OvERALL DEPth DImENsIONs 
sIDE vIEw
Electrical Circuit 
Required
Total Connected 
Load
 120 Vac, 60 Hz, 15 Amps., 
dedicated, grounded
4.0 Amps. @ 120 Vac, 
60 Hz
ELEctRIcAL REqUIREmENts
Document # PG05-001
Revised 05/06/09   Page 1/3