Wolf 801641 Benutzerhandbuch

Seite von 16
MODEL 804701
Page 2
OUTSIDE - ROOF VIEW
OUTSIDE - ROOF VIEW
10 Cover 
Screws
10 Cover 
Screws
Remove 
roofing 
nails from 
top 2/3 of 
shingles.
Bird Screen
Flashing
Sheet
Drill 6 
Mounting 
Holes
Damper
 
ROOF MOUNT
  INSTALLATION
For use with Models CTWH30, CTWH36, IH4227, W30-662418, W30-662718, I36-663418, 
L34-582212, DD30R, DD36R, DD45R.
PREPARE THE ROOF
WIRE THE VENTILATOR
11" dia.
hole
1"
20½"
18"
12
5
/
8
"
1¼" dia. hole
Roof Rafter
REMOVE SHINGLES
Roof   Rafter
12
11
/
16
"
21"
Pilot Hole
(centered
between rafters)
From inside the attic space:
1
  Drill a 
PILOT HOLE up through the roof, centered between 
ROOF RAFTERS.
From outside - on the roof:
2
  Measure and mark the 21" x 20½" rectangle. Cut and remove 
only the shingles inside this rectangle.
3
  Measure and mark the 
11" DIAMETER HOLE and the 1¼" 
DIAMETER HOLE. Cut these holes all the way through the 
roof.
For flat roof installations:
4
  Build a curb that will mount the blower at a minimum pitch of 
2/12. Discharge end of the blower should be pointed away 
from prevailing winds.
7"
2"
2 9
½
"
25"
2 "
BLACK TO BLUE
WHITE
TO
BROWN
120 
VAC
LINE
IN
GROUND
TO
GROUNDING
SCREW
INSTALL THE VENTILATOR
5
 Remove 
10 
COVER SCREWS 
and lift off 
ventilator cover.
6
  Feed the electric 
power cable 
through the 
1¼" 
DIAMETER HOLE 
and connect cable 
to ventilator with a 
proper connector 
for the type of 
cable being used.
Connect 
BLACK 
TO BLACK
WHITE TO BLUE
and 
GROUND 
TO GROUNDING 
SCREW.
8
  Remove roofing nails from top 2/3 of shingles around cut-out 
area.
9
  Slide the ventilator's 
FLASHING SHEET up and under the 
loosened shingles until ventilator's discharge collar fits into 
11" diameter hole.
10
  Use the 6 screws (provided) to attach the ventilator to the 
roof. 
DRILL 6 MOUNTING HOLES inside the ventilator, 
as necessary.
11
  Seal the screw heads, loosened shingles, and edges of 
the flashing sheet, with a good grade of roofing cement.
12
  Check for free movement of the spring-loaded 
DAMPER
and re-install the ventilator cover. Turn on power and check 
operation.
BLACK TO BLACK
WHITE
TO
BLUE