Capital COB484BBSSL Benutzung Und Pflege

Seite von 57
 
 
42  
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING. 
 
UNPACKING AND HANDLING 
1.  Move the oven as close to the point of installation as possible prior to removing packing materials to prevent 
damage. 
2.  Remove all packing materials from inside the oven and any protective plastic on the outside of the oven. 
3.  Read and retain all instructions before installation and use and after installation as a reference. 
4.  The units are heavy. Plan sufficient manpower and use caution when lifting the unit. 
ELECTRICAL WIRING INSTALLATION: 
WARNING: 
1.  All wiring must comply with all local ordinances and building codes. 
2.  Electrical services at the installation must meet or exceed those specified for the appliance. Do not proceed 
with the installation until the specifications are met. Call a licensed electrician, if required, to meet the 
necessary requirements.  
3.  To prevent electric shock or fire hazard, turn off power at the circuit breaker or fuse box prior to connecting 
the oven. 
4.  Improper connection of the electrical wiring can cause an electric shock hazard and damage the appliance. 
Capital Cooking Equipment is not responsible for damages resulting from improper installation. 
5.  The ground wire of the oven must be connected to a grounded metallic, permanent wiring system or 
grounding conductor. 
6.  Do not use an extension cord with this appliance. Fire, electric shock or other personal injury or damage 
may occur as a result. 
7.  Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an 
electric shock hazard. 
8.  Use copper wire only when connecting the oven to the circuit breaker or fuse. 
9.  Flexible armored or non-metallic, sheathed copper cable (with grounding wire) should be used to connect 
the appliance to the circuit breaker or junction box. A UL listed connector must be used if directly connecting 
the wiring to the junction box. 
IMPORTANT
Prior to installation and preparation of the wiring, power to the planned oven electrical circuit must 
be turned off at the breaker or fuse box. 
ELECTRICAL REQUIREMENTS:
 
Electrical Requirement Summary Table 
Model: 
COB / CSB 30/36 
COB / CSB 48/60 
Type: 
Single Oven Range 
Double Oven Range 
Voltage: 
240 VAC 
240 VAC 
Frequency: 
60 Hz, Single Phase 
60 Hz, Single Phase 
Total Connected Load: 
36.3 Amp 
49.1 Amp 
Circuit Breaker Req.: 
40 Amp (Dedicated) 
50 Amp (Dedicated) 
Wire Connection: 
4 Wire 